VoiceAlert
2
User Manual
disarm their own room (zone) when coming and going, without interfering with the rest of the guests’ rooms
(zones)).
Background info:
VA
2
zones can be allocated to eight different groups for arming and disarming. Eight
different remotes corresponding to groups 1 to 8 can be use to arm and disarm. Manual arming and
disarming can also be performed via the VA
2
’s keypad (requires password) and or any telephone keypad if
telephonic control is installed (requires password).
Function Options:
1. Set specific zones, for uniform arming disarming (i.e. these zone do not fall within a specific group
and will always arm and disarm regardless of which remote is used to do arming disarming).
2. Allocate specific zones to one of eight different groups for manual arming / disarming (when using
remotes, remote one will control Group1 zones as well as any uniform non-grouped zones. Remote
2 controls Group2 specific zones as well as any uniform zones. Etc. Etc. ……Remote 8 controls
Group8 and the uniform zones).
Procedure - Set Function 1
(e.g. allocate zones 1, 2, 3 and 9 to for uniform arming / disarming)
:
•
Press
Return
(Inverted Arrow)
•
Press
PRG
•
Enter
15
•
Press
OK
•
Enter 1239
•
Press
OK
•
LCD will Display as above
•
Press
Return
to exit
Procedure – Set Function 2
(e.g. allocate zones 1&2 to uniform, zone 3 to Group1, zone 9 to Group2 and
zone 4 to Group3)
:
•
Press
Return
(Inverted Arrow)
•
Press
PRG
•
Enter
15
•
Press
OK
•
Enter 12
•
Enter *
•
Enter 3
•
Enter *
•
Enter 9
•
Enter *
•
Enter 4
•
Press
OK
•
LCD will Display as above but with 12*3*9*4
•
Press
Return
to exit
Related configuration codes
(You may need to set the following related configurations):
•
10
•
13
•
14
Copyright InFocus Trading 111 cc, 2009