Shadow VI User Manual
1107200
Introduction to Shadow VI
Chapter 1
page 13
Safety Light Curtain
Shock testing
50g, 11ms pulse per MIL-STD-810 C, Method 516,
Procedure I (applies to all three axes).
Operating Temperature
- 4° F to 122° F (-20° to 50° C).
Inputs
Power
Heads
MPCE
Remote Reset
115-230 VAC (DC available)
50-60 Hz; 30 VA max.
Two sets (any height) can be connected to same control.
Monitor input: For external dry contacts rated at 20 mA @
20 VDC; 25 msec. response time max.
Closure to ground ON voltage 2V @ 2mA
Light Source
Infrared light emitting diodes (LEDs).
Approximately 850 nanometer wavelength
Optics
Angle of Divergence and Acceptance: less than ± 3.5°.
Outputs
Stop Circuit/status
Indicator Outputs*
2 "captive contact" stop relays and one status relay, plus 4
solid state indicator outputs.
4A @ 120 VAC or DC resistive max; N/O and N/C
contacts with all 3 relays.
4 open collector, NPN, opto-isolated outputs can switch
70 V load @ 2 mA maximum
(see warning below).
Indicators
Transmitter
Receiver
Control
Amber (power).
Red "obstructed"; Amber "floating enabled"; Green "clear
unobstructed".
Red "obstructed"; Amber "floating enabled"; Green "clear
unobstructed"; Yellow "Reset required".
Summary of Contents for Shadow VI
Page 142: ...1107200 Shadow VI User Manual page 130 Appendix C Installation of Shadow VI WPC Control Board ...
Page 144: ...1107200 Shadow VI User Manual page 132 Appendix D Replacement Parts ...
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 159: ......