background image

ILLUMINATED MIRRORS - LED with Bluetooth   wireless technology stereo speakers 

Please read these instructions carefully before starting installation and keep in a safe place for future reference.

Check the contents of the pack carefully before installation. Responsibilty will not be held for any de-fit / re-fit costs where faulty product has 

been fitted. If any fault is found with materials or workmanship, it must be reported immediately to the manufacturer. Remedial action will be 

taken, based on information received, on condition that: 1. Full details are supplied to the manufacturer; 2. The product has not been 

modified or tampered with; 3. The manufacturer is informed of any damage/shortages prior to installation. 4. The product has not been 

installed, or attempts have been made to install. We do not accept responsibility for any problems that may occur through 

incorrect installation. ENSURE the room is well heated and ventilated.

Before drilling ensure there are no hidden cables or pipes(water, gas or electrical) behind hanging points. Always wear 

suitable eye protection when drilling.Ensure the wall surface is able to take the weight of the complete product.

It is important to install light fittings in the correct bathroom zone i.e. the zone referred to in the IP rating of the element. This is not an 

installation guide and reference should be made to the latest edition of the IET Wiring Regulations or a qualified electrician member of 

NICEIC or IET.

ZONE 0 is inside the bath or shower tray itself. Any appliance used in this zone must be rated at least IP67 which is total immersion proof.

ZONE 1 is the area above the bath or shower tray to a height of 2.25m from the floor. In this zone a minimum rating of IPX4 Splash-proof 

is required and elements must also be protected by a 30mA residual current device (RCD) to protect the circuit. 

The electrical connection to the power supply for these appliances must be in Zones 2/3 of the bathroom in compliance with 

BS 7671:2008(2011) - IET Wiring Regulations.

ZONE 2 is an area stretching 0.6m outside the perimeter of the bath and to a height of 2.25m from the floor. In this zone an IP rating of at 

least IP44 is required. In addition it is good practice to consider the area around a washbasin, within a 60cm radius of any tap to be 

considered as zone 2.

Appliance must also be protected by a 30mA residual current device (RCD) to protect the circuit.

Failure to have electrical products installed and certificated by a qualified electrical engineer will invalidate any product guarantee.

For full details reference should be made to the latest copy of the IET wiring regulations and all applicable British Standard and European 

norm specifications.

WIRING DIAGRAM

IMPORTANT ADVICE & SAFETY - please read before installation

This product is Class I rated

and MUST be earthed. 

Supply 240v/50hZ maximum 

This product is IP44 rated and is suitable for installation within zone 2 above, and complies with the following safety standards:

BS EN 60598-1: 2008+A11: 2009, EN60598-2-1: 1989 

LIVE

EARTH

NEUTRAL

Live supply-Red or brown

Earth supply-Green/yellow
Neutral supply-Black or blue

Live - brown

Earth -Green&yellow

Neutral - blue

®

Summary of Contents for MEB8060A

Page 1: ...ath or shower tray itself Any appliance used in this zone must be rated at least IP67 which is total immersion proof ZONE 1 is the area above the bath or shower tray to a height of 2 25m from the floor In this zone a minimum rating of IPX4 Splash proof is required and elements must also be protected by a 30mA residual current device RCD to protect the circuit The electrical connection to the power...

Page 2: ...ecommended that walls are fully tiled finished before installation This ensures that the product is installed flat to the wall face and allows product to be easily removed if required in the future STEP 1 Offer the mirror frame up to the desired wall location considering the safety zone requirements Using spirit level ensure the frame is level and upright Using a soft pencil markcarefully the 4 fi...

Page 3: ...ite this in bold type face Do not strike hit glass components with hard or pointed items Do not place very hot or very cold items against or in close proximity to glass surfaces unless a suitably thick insulation material is used The nominal thickness of the mirror glass used in this product is 5mm and is safety film backed in accordance to BS EN6206 for your safety If the mirror glass becomes chi...

Page 4: ... uk Crosswater Holdings Copyright No part of this document may be reprinted or duplicated without Crosswater Holding s consent In the interests of continued product development Crosswater Holdings reserves the right to alter specification without prior notification E OE MEB8060A square corners MEB8060B radius corners ...

Reviews: