Appendix A
Excerpts from OSHA Regulations and
ANSI
Standards
Daily Tests in French and English
Extracts from ANSI B11.19-2003 8.3
Standards Requirements
Explanatory Information
8.3.2.8
The total tolerance in the range
measurement of an area scanning device shall
be included in determining the distance from
the nearest recognized hazard to the detection
area or zone. This detection area shall be
identified and tested to ensure that the device is
able to detect individuals entering the detection
area. The effective sensing field shall be
verified for proper size and coverage upon
installation, replacement, or changes of the
detection area.
E8.3.2.8
When the device is horizontally
mounted, the detection area or zone should be
visibly marked on the floor. This verification can
be accomplished by using a programming
device or by physically identifying the perimeter
of the detection area with an appropriate test
rod, following the supplier's recommendation.
This verification is to ensure that a
preprogrammed device with a small or improper
detection area is not used by mistake in an
installation requiring a larger field.
Area scanners may not be suitable (effective)
safeguards when used to protect an individual's
hands or fingers from hazards.
Items which can affect this suitability are:
response time;
minimum object sensitivity;
measurement accuracy.
Summary of Contents for Shadow VI
Page 142: ...1107200 Shadow VI User Manual page 130 Appendix C Installation of Shadow VI WPC Control Board ...
Page 144: ...1107200 Shadow VI User Manual page 132 Appendix D Replacement Parts ...
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 159: ......