Inside the Control
There are eight LED indicators on the circuit board inside the control (refer to Figure 2-14 in
Chapter 2 for location of components).
DS1
and
DS2
are located just above the TB2 receiver connectors at the lower right-hand
corner of the board, and do not light up under normal conditions. However, they light up
red
if you are using only 1 set of curtains and there is an obstruction. If you have 2 sets, DS1
lights up red when Set 1 (wired to the upper connectors of TB2 and TB3) is interrupted. DS2
corresponds with Set 2, which are wired to the lower connectors.
DS3
and
DS4
, located in the upper right-hand corner of the control near the power supply,
normally light up
green
all the time, indicating that the optic heads are receiving power.
DS5
and
DS6
are located in the lower left corner of the board below TB4. They light up
orange
when you are using external MPCE monitoring and there is an obstruction in the
light field. See “External MPCE Monitoring: Checking DS5 and DS6” on page 85.
DS7
is located in the lower left corner of the board below TB4. It is off under normal
conditions, but lights up
yellow
when “Reset” is on.
DS8
is located in the lower left corner of the board. Under normal conditions, it lights up
green
, indicating that the transmitter is active.
Summary of Contents for Shadow VI
Page 142: ...1107200 Shadow VI User Manual page 130 Appendix C Installation of Shadow VI WPC Control Board ...
Page 144: ...1107200 Shadow VI User Manual page 132 Appendix D Replacement Parts ...
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 159: ......