18 

WILO SE 06-2016 V5.0 DIN A4

English 

PRODUCT DESCRIPTION

health must be generally decontaminated before 

being used in other media.

Clarification must be sought as to whether the 

aeration systems may be used again at all, in 

another medium.

• Consult Wilo customer service for use in highly 

flammable, explosive and/or aggressive media!

3.  Product description

3.1.  Intended use

Wilo-Sevio AIR D aerators and aeration systems 

are used for air intake of large to fine bubble air 

in aqueous media such as water, pre-purified 

sewage or sludge, for the purpose of supplying 

oxygen.

Use only in industrial sewage after consulting 

Wilo customer service!

The media temperature must be b5 °C 

and +30 °C. Wilo customer service must be con

-

sulted for use in media with higher temperatures. 

In addition, the surrounding medium must be free 

of any sharp objects. It is recommended to carry 

out mechanical cleaning upstream.

The supplied air must not exceed a max. temper-

ature of +60 °C (for higher temperatures please 

consult Wilo customer service), must be free of 

oil, dust and solvents. Dust filters must comply 

with filter class EU4 according to DIN 24185 

 

(degree of separation >90 %).

All filters and insulating material used must not 

consist of fibreglass, mineral fibres or other 

fibrous materials. Rotary slide valves with graphite 

discs must be equipped with an air filter on the 

pressure side.

These materials can clog or damage the  

diaphragms.

3.2.  Improper use

Aerators and aeration systems must 

not

 be used 

in:

• 

Media containing fats and oils (above 25 ppm)

• Media with organic solvents

• Halogenated compounds

• Anaerobic milieu

3.3.  Set-up

The Wilo-Sevio AIR D aeration system is com-

posed of one or more aerator fields with multiple 

aerator lines. An aerator field forms the basic unit 

here and consists of several components.

3.3.1.  Pipework

The pipework consists of individual pipes made 

of stainless steel or plastic. Here, a distinction is 

made between the air distributor and the pipes 

for the aerator lines.

The air distributor has a flange connection for the 

connection to the downpipe on-site.

The pipework for aerator lines is connected to the 

air distributor via T-connectors. The individual 

aerator lines are connected using connecting 

sleeves.

Sealing plugs are placed at the ends of the pipe-

work.

The drainage pipe is connected to a central pipe 

(air distributor or connection at the end of the 

aerator lines). This can be used to drain the con-

densate which can form during aeration.

3.3.2. 

Floor fixation

The threaded rods are used to attach the com-

plete pipework to the bottom of the basin. These 

also enable levelling of the aerator groups.

3.3.3.  Disc diffuser

The housing components are made of PP-30GF, 

the membrane is made of EPDM or silicone.  

A threaded flange with a male thread is cast on to 

the housing.

The disc diffuser is installed via a mounting base 

made of EPDM with female thread.

3.4.  Function

A fan or compressor pumps air into the air 

distributor via the inlet pipe. The air distributor 

distributes the air evenly to the individual aerator 

pipes and the disc diffusers. The disc diffus-

ers distribute the air over the entire diaphragm 

surface and channel it into the fluid.

3.5.  Type key

Example: Wilo-Sevio AIR D295-ES-S-150

Sevio

Products for sewage treatment

AIR

Aerator series

D

Disc diffuser

295

Diameter of the perforated area in mm

ES

Membrane material:

ES = EPDM standard

ER = EPDM with reduced plasticizer

S = Silicone

S

System

150

Number of aerators per system

3.6.  Technical data

• 

Outer diameter: 9“ or 12“

• 

Male thread: ¾“

• 

Size of the air bubbles: 0.5…1.0 mm or 

1.25…1.75 mm

• 

Max. air temperature: +60 °C

• Loading range 

9“

-aerator

• 

Air volume range: 1.5…7 m³/h

• 

Standard loading: 4.5 Nm³/h

• 

Max. loading: 10 Nm³/h

• Loading range 

12“

-aerator

• 

Air volume range: 5…12 m³/h

• 

Standard loading: 9 Nm³/h

• 

Max. loading: 15 Nm³/h

 

Summary of Contents for Wilo-Sevio AIR D

Page 1: ...02 06 2016 WH Pioneering for You Wilo Sevio AIR D de Einbau und Betriebsanleitung en Installation and operating instructions es Instrucciones de instalaci n y funcionamiento hu Be p t si s zemeltet s...

Page 2: ......

Page 3: ...4 Funktion 6 3 5 Typenschl ssel 7 3 6 Technische Daten 7 3 7 Lieferumfang 7 3 8 Bauseits zustellendes Material 7 4 Transport und Lagerung 7 4 1 Transport 7 4 2 Lagerung 7 5 Aufstellung 7 5 1 Allgemei...

Page 4: ...ch auf die im Titelblatt angegebenen Bel fter 1 5 Gew hrleistung Generell gelten bez glich Gew hrleistung die Angaben laut den aktuellen Allgemeinen Ge sch ftsbedingungen AGB Diese finden Sie hier www...

Page 5: ...Symbol f r Gebot z B K rperschutz tragen Die verwendeten Zeichen f r die Sicherheits symbole entsprechen den allgemein g ltigen Richtlinien und Vorschriften z B DIN ANSI Sicherheitshinweise die nur au...

Page 6: ...en Die zugef hrte Luft darf eine max Temperatur von 60 C haben bei h heren Temperaturen halten Sie bitte R cksprache mit dem Wilo Kun dendienst muss frei von l Staub und L sungs mitteln sein Staubfilt...

Page 7: ...nde Tragf higkeit und Tragkraft besitzen damit ein Bel fterfeld und dessen Zubeh rteile gefahrlos transportiert werden k nnen Das Personal muss f r diese Arbeiten qualifiziert sein und muss w hrend de...

Page 8: ...g in Form von Abmessungen Festigkeit und Belastbarkeit ist der Betreiber bzw der jewei lige Zulieferer verantwortlich 5 3 1 Bauseits zustellendes Material Zulaufleitung f r Luftzufuhr Das Bel fterfeld...

Page 9: ...r bundanker und Befestigen Sie die Halterung mit einer Scheibe und Sechskantmutter 5 Drehen Sie pro Gewindestange zwei Sechskant muttern auf stecken Sie jeweils eine Unterleg scheibe auf und stecken S...

Page 10: ...halten und berpr ft werden Kompressor Gebl se hat eine ausreichende Leis tung f r die erforderliche Luftzufuhr Druck in der Zulaufleitung entspricht der Vorgabe und bleibt konstant Verrohrung ist abso...

Page 11: ...eist kann die Anlage in Betrieb gehen Nachdem auch der zweite Funktionstest erfolg reich abgeschlossen wurde muss der Betriebs raum geflutet werden Sollte die Inbetriebnahme noch nicht m glich sein mu...

Page 12: ...grund abstellen und ge gen Umfallen sichern Bauteile vor direkter Sonneneinstrahlung sch t zen um der Verspr dungsgefahr der Kunststoff teile vorzubeugen Beachten Sie hierzu auch das Kapitel Transport...

Page 13: ...rt werden Die Wartungsintervalle m ssen entsprechend der Beanspruchung des Bel ftersystems festge legt werden Unabh ngig von den festgelegten Wartungsintervallen ist eine Kontrolle des Bel f tersystem...

Page 14: ...olen Sie diese Schritte 3 4 mal Der max zul ssige Wert f r die Beaufschlagung darf nicht berschritten werden Da diese Wartungsma nahme erheblich zur Funktionssicherheit und Effizienz der Anlage beitr...

Page 15: ...nction 18 3 5 Type key 18 3 6 Technical data 18 3 7 Scope of delivery 19 3 8 Material to be provided by the customer 19 4 Transportation and storage 19 4 1 Transport 19 4 2 Storage 19 5 Installation 1...

Page 16: ...be given priority 1 5 1 General The manufacturer is obliged to correct any de fects found in the aerator it sells provided that the defects meet one or more of the following requirements The defects a...

Page 17: ...ng faeces activated sludge with bacteria etc particular caution must be taken Open wounds must be cleaned and treated immediately Eating and drinking is strictly prohibited Appropriate protective equi...

Page 18: ...mponents 3 3 1 Pipework The pipework consists of individual pipes made of stainless steel or plastic Here a distinction is made between the air distributor and the pipes for the aerator lines The air...

Page 19: ...ersons The safety instructions must be followed at all times The components of the aeration system must be inspected for transport damage before carrying out any installation work 5 1 General For desi...

Page 20: ...the installation check the operat ing space to see if it is prepared accordingly for the installation The configuration of the system as well as the installation and drilling plans are in line with th...

Page 21: ...the outside of the pipe ends of the aera tor pipe as well as the inside of the connecting sleeves with a liquid soap solution no grease or oil 4 Slide the connecting sleeves onto an aerator pipe as fa...

Page 22: ...must be present in the basin and drain the aerator fields during the function test A visual inspection from the corners or outside the operating space is not permitted 1 Before water is introduced int...

Page 23: ...a 10 minute test run with maximum loading must be per formed daily 7 2 Decommissioning for maintenance work and or storage The system must be switched off and secured against being switched on again w...

Page 24: ...media hazard ous to health must be decontaminated In addi tion make sure that no gases that are hazardous to health form or are present DANGER due to toxic substances During work in an environment haz...

Page 25: ...drainage pipe during the test run The air supply in the aeration system causes water condensate that may be present to discharge via the drainage pipe 8 2 3 Cleaning the diaphragm surface During opera...

Page 26: ......

Page 27: ...C digo 31 3 6 Datos t cnicos 31 3 7 Suministro 31 3 8 Material que corre a cargo del propietario 31 4 Transporte y almacenamiento 31 4 1 Transporte 31 4 2 Almacenamiento 31 5 Instalaci n 31 5 1 Genera...

Page 28: ...de venta actualizadas Estas pueden consultarse en www wilo com legal Cualquier divergencia al respecto deber es tipularse contractualmente y d rsele un trato prioritario 1 5 1 Generalidades El fabrica...

Page 29: ...os s mbolos de segu ridad cumplen con las directivas y normativas de validez general p ej DIN ANSI Las indicaciones de seguridad que solo hacen referencia a da os materiales aparecen en color gris y s...

Page 30: ...re introducido debe tener una temperatura m x de 60 C en caso de temperaturas supe riores consultar con el servicio t cnico de Wilo y debe estar libre de aceite polvo y disolventes Los filtros de polv...

Page 31: ...elevaci n previstos y homologados Deben tener una capacidad de carga suficiente para poder trans portar con seguridad una parrilla de aeraci n y sus correspondientes accesorios El personal debe estar...

Page 32: ...la carga no se desplace durante el transporte Los elementos constructivos y los cimientos deben tener la suficiente resistencia como para permitir una fijaci n segura que garantice el funcionamiento E...

Page 33: ...de marca y coincidir con el esquema de perforaciones enviado ya que en caso contrario pueden surgir torsiones durante el montaje 2 Limpiar las perforaciones exhaustivamente p ej aspir ndolas 3 Instale...

Page 34: ...r la tuber a cerrarla de nuevo por completo 7 Girar el difusor de plato hasta el tope en los so portes de fijaci n 6 Puesta en marcha El cap tulo Puesta en marcha contiene todas las instrucciones impo...

Page 35: ...aso se aumenta el nivel de agua hasta aprox 10 cm por encima de la uni n por bridas del distribuidor de aire y el tubo de entrada Compruebe la estanqueidad del distribuidor de aire y de la conexi n de...

Page 36: ...ecesario llevar los equipamientos de pro tecci n correspondientes en cada caso Al abandonar la instalaci n es necesario desin fectar a las personas y las herramientas 7 2 1 Desmontaje El desmontaje se...

Page 37: ...ridas abiertas deben limpiarse y tratarse inmediatamente Est prohibido ingerir comida o bebida en todo momento Es necesario llevar los equipamientos de pro tecci n correspondientes en cada caso Al aba...

Page 38: ...desag e durante la puesta en funcionamiento Debido a la entrada de aire en el sistema de ventilaci n se evacua agua condensados existentes a trav s de la tuber a de desag e 8 2 3 Limpieza de la super...

Page 39: ...M k d s 42 3 5 A t pusjel magyar zata 42 3 6 M szaki adatok 43 3 7 Sz ll t si terjedelem 43 3 8 Az gyf l ltal biztos tand anyagok 43 4 Sz ll t s s rakt roz s 43 4 1 Sz ll t s 43 4 2 T rol s 43 5 Tele...

Page 40: ...an ltal noss gban az lta l nos Szerz d si Felt telek SZF c m doku mentum aktu lis v ltozat ban szerepl inform ci k rv nyesek Ezt itt tal lja meg www wilo com legal Az ett l val elt r seket szerz d sb...

Page 41: ...bet sz nnel szedt k s biztons gi jel n lk l jelennek meg 2 2 ltal nos biztons gi el r sok A diff zor medenc be t rt n be ill kiszerel s t tilos egyed l v gezni Mindig jelen kell lennie egy m sodik sz...

Page 42: ...las vagy m s finomsz las anyagb l k sz lt sz r k s szigetel anyagok haszn lata tilos A grafitlamell s forg tolatty s szelepeket nyom oldalon l gsz r vel kell ell tni Ezek az sszetev k a membr n elt m...

Page 43: ...szeket az eredeti csomagol sban kell t rolni A t rol helyis gnek sz raznak s fagymentesnek kell lennie 5 C s 25 C k z tti h m rs klet j l szell z helyis gben val t rol st javaslunk A h m rs klet nem...

Page 44: ...ke reszt l csatlakozik a bet pl l vezet khez A be t pl l vezet k helyzet n a megrendel s lead sa ut n m r nem lehet m dos tani mert k l nben ez probl m kat okozhat a telep t s sor n Ezen k v l a bet p...

Page 45: ...nden egyes cs vet pontosan v zszintesen kell be ll tani s minden leveg ztet fel letenek ugyanabban a magass gban kell lennie A meden cefen k s a cs tart k z tti sz ks ges t vols got a m retez si terve...

Page 46: ...ndszer zembe helyez s t kiz r lag szakk pzett s betan tott szem lyek v gezhetik a biztons gi el r sok betart sa mellett A leveg ztet rendszert kezel szem lyzet vala mennyi tagj nak meg kell kapnia el...

Page 47: ...d s ellen rz s sikeres elv gz se ut n a rendszer zembe helyezhet Ehhez a leveg z tet st egy k l n az p ttet ltal biztos tand kezel helyen kell bekapcsolni Alapvet en itt csak a Be s Ki zem llapotok k...

Page 48: ...valamint a tiszt t si s karbantart si munk k sor n viselt v d ruh za tot a TA 524 02 hullad kk d s a 91 689 EGK ir nyelv ill a helyi ir nyelvek szerint kell rtal matlan tani 7 4 2 Term k A term k el...

Page 49: ...llen rz se Karbantart si m veletek a l gs r t k n bef v kon Sz r csere a leveg bevezet sben 8 1 2 Zord zemi k r lm nyekre vonatkoz id k z k Zord zemi k r lm nyek eset n a megadott karbantart si id k z...

Page 50: ...csolatban l pjen kapcso latba a kezel hely gy rt j val 8 2 4 Membr nok fel let nek mechanikus tiszt t sa 1 Leveg ztet fel let kikapcsol sa 2 Medence leereszt se 3 Medence s diff zor lemos sa nagynyom...

Page 51: ......

Page 52: ...Pioneering for You WILO SE Nortkirchenstra e 100 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Reviews: