Manual: R4000-XX-X-000-X-X_EN
Release: 1.20
©Elotech GmbH
Seite 19 / 48
Window: Log (Logbook)
This window displays alarm- and status messages for all zones.
The header displays the current date and time,
the window number and page.
Pressing the log-texts displays the full text if it is
abbreviated in the normal display. See also
1)
The logbook can take up to 40 entries.
The latest entry can be found on page 1/5.
If 40 entries exist already, the oldest entry will be
deleted.
The logbook is stored in a power failure safe man-
ner.
Switching between the logbook-pages
”+“ previous page; ” - “ next page
1)
Alternatively press the upper or lower areas of the list for switching
pages. (Changeover only with a pushbutton pressure less than 1s,
otherwise only long-text display without page switchover)
Hold down < 1 sec. = Return to previous window
Hold down > 1 sec. = Jump to window “Actual Process Value“
Deletion of the logbook-entries
Window: Program (Program controller graph)
This image shows the graphical representation of the selected control program.
The header displays the current program, the cur-
rent step and the status.
Right above the graph is the indication of the cur-
rent program setpoint.
On the right side, the zones are displayed, whose
setpoints are specified by the program.
At the bottom (x-axis) the time is shown in hours.
The elapsed time is displayed as a blue ribbon.
Here on the left below the 105. The current time
is indicated by the thin blue line at the right end
of the tape.
These keys are used to control the program.
Stop Pause and Start.
If the program is stopped you will get to the menu for the program
controller via the Edit button.
If the total time of the program has expired (Stop displayed), the set-
point of the last program step is retained.
Hold down < 1 sec. = Return to previous window
Hold down > 1 sec. = Jump to window “Actual Process Value“