Manual: R4000-XX-X-000-X-X_EN
Release: 1.20
©Elotech GmbH
Seite 15 / 48
5.3
Adjusting windows
Window: Entering number value
This window helps entering number values, here for the setpoint 1.
The header displays the current zone and the
name of the Parameter, here “Setpoint 1 “.
By pressing the number keys the value of the pa-
rameters can be entered. In order to take over
the parameter value, it must be saved by pressing
the “SAVE”– key.
The value, entered by pressing the number keys, is now displayed
within the blue frame.
Underneath, on the left the unit is shown and the previous value is
displayed on the right (250).
The allowed range is displayed at the bottom (0...800).
If this Button is visible, two adjustable parameters are available.
Such as: Setpoint: 1 / 2 or Ramp: rising / falling
Switch over by pressing this button. The name of the actual parame-
ter is displayed in the header. After adjusting one parameter the win-
dow will not be closed and the second parameter can be adjusted.
This key is visible when the parameter has a valid value “OFF”.
“OFF” can be selected like a number key.
Number key
Key to enter “Minus” or “Comma”.
The minus sign can be pressed before entering a number. After the
first number was entered the key automatically changes to comma.
Delete last character
Return to previous window
Saving of what has been entered and return to previous window.
By pressing “SAVE” for > 1s., a selection window appears, in which
parameter values can be saved for other zones simultaneously.
See 5.3.4 Window: Saving to multiple zones.