Song Meter SM4BAT FS User Guide
4 Settings
Wildlife Acoustics, Inc.
page
22
the maximum duration, and within the frequency range you specified. If two
such signals exist, the file is saved; otherwise, the file is not saved.
A value of
1.5 ms is recommended for recording bats.
NOTE
: To disable the scrubber, set
Min Duration
and
Max Duration
to
none
.
Range
: none, 0.1 to 99.9 milliseconds in 0.1-millisecond increments
Default
: 1.5 ms
Max Duration
Sets the maximum duration of a signal in the specified frequency range that
qualifies as a valid signal for the scrubber. A value of
none
is recommended for
recording bats.
Range
: none, 1 to 500.0 milliseconds in 1-millisecond increments
Default
: none
Min Trig Freq
Use this command to set the lower bound for the frequencies of interest to the
triggering mechanism and noise scrubber. Echolocation calls or other signals
occurring below this frequency do not cause a trigger and are considered noise
to the scrubber. A setting of 16 kHz works well for most bat applications. It may
be necessary to reduce this setting for recording lower-frequency species.
Range
: 6 to 99 kHz in 1-kHz increments
Default
: 16 kHz
Trigger Level
Specifies the digital trigger level. The trigger is satisfied if a signal exceeds the
specified dB level and is above the frequency defined by
Min Trig Freq
. The
recorder creates an individual time-stamped WAV file for each triggered event
during the scheduled recording period.
NOTE:
The trigger is inactive for up to a second after the end of a triggered recording
to allow time for the file to be written.
Turning on the trigger also activates file scrubbing. For information on the
scrubber, including how to turn it off, see
Min Duration
.
When you turn off the
Trigger Level
setting, the
Trigger Window,
Min Trig
Freq, Min Duration
,
and
Max Duration
settings are ignored and continuous
recordings are made as defined in the recording schedule and subject to the
Max Length
setting.
Range
: off, 6, 12, 18, or 24 dB
Default
: 12 dB