VIP 110-24
Operator’s Manual (rev E)
- 48 -
unlock
enable-configuration=”ASCII string”
This command, with the correct password, unlocks the access to the commands that allow the
radio configuration to be altered.
Examples:
>
unlock enable-configuration=bh7g8
6.4
Major Configuration Parameters
These commands change several operating parameters of the radio that are part of the radio
“configuration”. When entering commands with multiple parameters, if a parameter is not
included, that parameter keeps its current value.
max-flow-rate
transmit-kbps=1…10000
Specifies the maximum data rate that the radio will accept from its Ethernet port to be offered
into the VINE RF network, even during idle periods.
receive-kbps=1…10000
Specifies the maximum data rate that the anchor radio will accept from its Ethernet, addressed
to this specific node, even during idle periods.
Examples:
> max-flow-rate receive-kbps=1024
> maxfl tr=512 re=256
min-flow-rate
transmit-kbps=1…8000
Specifies the minimum data rate that the radio will accept from the Ethernet port to be offered
into the VINE network, even during congested periods. This is equivalent to the “Committed
Information Rate (CIR)” in a frame relay environment.
receive-kbps=1…8000
Specifies the minimum data rate that the anchor radio will accept from its Ethernet, addressed
to this specific node, even during congested periods. This is equivalent to the “Committed
Information Rate (CIR)” in a frame relay environment.
Examples:
> min-flow-rate transmit-kbps=500
Summary of Contents for VIP 110-24
Page 2: ......
Page 5: ...VIP 110 24 Operator s Manual rev E iv...
Page 37: ...VIP 110 24 Operator s Manual rev E 30...
Page 73: ...VIP 110 24 Operator s Manual rev E 66...
Page 89: ...VIP 110 24 Operator s Manual rev E 82...
Page 91: ...VIP 110 24 Operator s Manual rev E 84...