11
3 Product description
WIKA Operating Instructions - Process pressure transmitter CPT-2x
2
3
4
1
5
Fig. 5: Front-flush installation of the measuring cell (example: thread G1½)
1 Seal for the process fitting
2 Measuring cell
3 Seal for the measuring cell
4 Process fitting
5 Diaphragm
The completely front-flush mounting is particularly suitable for ap
-
plications in the paper industry. The diaphragm is in the pulp flow, is
hence cleaned and protected against buildup.
1
2
3
4
5
Fig. 6: Front-flush installation of the measuring cell (example: M30 x 1.5)
1 Measuring cell
2 Seal for the measuring cell
3 Seal for the process fitting
4 Process fitting
5 Diaphragm
The front-flush installation is particularly suitable for applications with
viscous media. The additional, front sealing protects the glass joint
of the measuring cell against chemical attack and the measuring cell
electronics against diffusion of aggressive gases from the process.
1
2
3
4
5
Fig. 7: Front-flush installation of the measuring cell with double seal (example:
flange connection with extension)
1 Measuring cell
2 Seal for the measuring cell
3 Process fitting
4 Additional, front seal for measuring cell
5 Diaphragm
Completely front-flush
mounting with single seal
Front-flush mounting with
double seal