6-6
n
HybridCare™ Dryer with Heat Pump Technology
TESTING
For Service Technician Use Only
TEST #2 Supply Connections
This test assumes that proper voltage is present at the outlet,
and a visual inspection indicates that the power cord is
securely fastened to the terminal block.
U.S. Installations:
1. Unplug dryer or disconnect power.
2. Remove the cover plate from the top right corner of the
back of the dryer. See figure 1.
3$*(
FOR SERVICE TECHNICIAN’S USE ONLY
DO NOT REMOVE OR DESTROY
¾
If +5VDC is still missing, unplug dryer or
disconnect power and replace the CCU.
¾
If +5VDC returns, unplug dryer or
disconnect power and check harnesses
and connections between the CCU and user
interface (UI). If acceptable, replace the UI.
8.
CCU +12VDC
– with voltmeter set to
DC
,
connect black probe to CCU P5-3 (ground)
and red probe to P5-8 (+12VDC). Plug in
dryer or reconnect power.
¾
If +12VDC is present, go to step 9.
¾
If +12VDC is not present, unplug dryer
or disconnect power and replace the CCU.
9.
Unplug dryer or disconnect power.
10.
Reassemble all parts and panels.
11.
Perform steps under “Install Diagnostics”,
page 6, to verify repair.
TEST #2: Supply Connections
This test assumes that proper voltage is present
at the outlet, and a visual inspection indicates
that the power cord is securely fastened to the
terminal block.
U.S. Installations:
1.
Unplug dryer or disconnect power.
2.
Remove the cover plate from the top right
corner of the back of the dryer. See figure 3.
3.
With an ohmmeter, check for continuity
between the neutral (N) terminal of the plug
and the center contact on the terminal block.
See figure 4a.
¾
If there is no continuity, replace the power
cord and test the dryer.
¾
If there is continuity, go to step 4.
4.
In a similar way, check which terminal of
the plug is connected to the left-most contact
on the terminal block and make a note of
it. This will be L1 (black wire) in the wiring
diagram. See figure 4a.
¾
When this is found, go to step 5.
¾
If neither of the plug terminals have
continuity with the left-most contact of the
terminal block, replace the power cord and
retest dryer.
5.
Access the machine electronics without
disconnecting any wiring to the CCU.
6.
With an ohmmeter, check for continuity
between the L1 terminal of the plug (found
in step 4) and P9-2 (black wire) on the CCU.
¾
If there is continuity, go to step 7.
¾
If there is no continuity, check that wires to
the terminal block are mechanically secure.
If so, replace the main wire harness and
test the dryer.
7.
Check for continuity between the neutral
(N) terminal of the plug and P8-3 (white wire)
on the CCU.
¾
If there is continuity, go to step 8.
¾
If there is no continuity, and the mechanical
connections of the wire are secure, replace
the main wire harness.
8.
Visually check that ALL connectors are
fully inserted into the CCU.
9.
Visually check that ALL connectors are
fully inserted into the UI.
10.
Reassemble all parts and panels.
11.
Plug in dryer or reconnect power.
12.
Perform steps under “Install Diagnostics”,
page 6, to verify repair.
Canadian Installations:
1.
Unplug dryer or disconnect power.
2.
Remove the cover plate from the top right
corner of the back of the dryer. See figure 3.
3.
Access the machine electronics without
disconnecting any wiring to the CCU.
4.
With an ohmmeter, check the continuity
from L1 and N plug terminals of the power
cord to the terminals for L1 and N on the
CCU. See figure 4b, page 12.
Figure 3 - Remove the cover plate.
COM
N
L1
Figure 4a - Plug-to-terminal connections
for electric dryer.
Power Cord
Plug
Terminal Block
Cover Plate
Remove Screw
Figure 1 - Remove the cover plate.
3. With an ohmmeter, check for continuity between the
neutral (N) terminal of the plug and the center contact on
the terminal block. See figure 2.
¾
If there is no continuity, replace the power cord and
test the dryer.
¾
If there is continuity, go to step 4.
4. In a similar way, check which terminal of the plug is
connected to the left-most contact on the terminal block
and make a note of it. This will be L1 (black wire) in the
wiring diagram. See figure 2.
¾
When this is found, go to step 5.
¾
If neither of the plug terminals have continuity with
the left-most contact of the terminal block, replace the
power cord and retest dryer.
3$*(
FOR SERVICE TECHNICIAN’S USE ONLY
DO NOT REMOVE OR DESTROY
¾
If +5VDC is still missing, unplug dryer or
disconnect power and replace the CCU.
¾
If +5VDC returns, unplug dryer or
disconnect power and check harnesses
and connections between the CCU and user
interface (UI). If acceptable, replace the UI.
8.
CCU +12VDC
– with voltmeter set to
DC
,
connect black probe to CCU P5-3 (ground)
and red probe to P5-8 (+12VDC). Plug in
dryer or reconnect power.
¾
If +12VDC is present, go to step 9.
¾
If +12VDC is not present, unplug dryer
or disconnect power and replace the CCU.
9.
Unplug dryer or disconnect power.
10.
Reassemble all parts and panels.
11.
Perform steps under “Install Diagnostics”,
page 6, to verify repair.
TEST #2: Supply Connections
This test assumes that proper voltage is present
at the outlet, and a visual inspection indicates
that the power cord is securely fastened to the
terminal block.
U.S. Installations:
1.
Unplug dryer or disconnect power.
2.
Remove the cover plate from the top right
corner of the back of the dryer. See figure 3.
3.
With an ohmmeter, check for continuity
between the neutral (N) terminal of the plug
and the center contact on the terminal block.
See figure 4a.
¾
If there is no continuity, replace the power
cord and test the dryer.
¾
If there is continuity, go to step 4.
4.
In a similar way, check which terminal of
the plug is connected to the left-most contact
on the terminal block and make a note of
it. This will be L1 (black wire) in the wiring
diagram. See figure 4a.
¾
When this is found, go to step 5.
¾
If neither of the plug terminals have
continuity with the left-most contact of the
terminal block, replace the power cord and
retest dryer.
5.
Access the machine electronics without
disconnecting any wiring to the CCU.
6.
With an ohmmeter, check for continuity
between the L1 terminal of the plug (found
in step 4) and P9-2 (black wire) on the CCU.
¾
If there is continuity, go to step 7.
¾
If there is no continuity, check that wires to
the terminal block are mechanically secure.
If so, replace the main wire harness and
test the dryer.
7.
Check for continuity between the neutral
(N) terminal of the plug and P8-3 (white wire)
on the CCU.
¾
If there is continuity, go to step 8.
¾
If there is no continuity, and the mechanical
connections of the wire are secure, replace
the main wire harness.
8.
Visually check that ALL connectors are
fully inserted into the CCU.
9.
Visually check that ALL connectors are
fully inserted into the UI.
10.
Reassemble all parts and panels.
11.
Plug in dryer or reconnect power.
12.
Perform steps under “Install Diagnostics”,
page 6, to verify repair.
Canadian Installations:
1.
Unplug dryer or disconnect power.
2.
Remove the cover plate from the top right
corner of the back of the dryer. See figure 3.
3.
Access the machine electronics without
disconnecting any wiring to the CCU.
4.
With an ohmmeter, check the continuity
from L1 and N plug terminals of the power
cord to the terminals for L1 and N on the
CCU. See figure 4b, page 12.
Figure 3 - Remove the cover plate.
COM
N
L1
Figure 4a - Plug-to-terminal connections
for electric dryer.
Power Cord
Plug
Terminal Block
Cover Plate
Remove Screw
Figure 2 - Plug-to-terminal connections for electric dryer.
5. Access the machine electronics without disconnecting any
wiring to the CCU.
6. With an ohmmeter, check for continuity between the L1
terminal of the plug (found in step 4) and P9-2 (black wire)
on the CCU.
¾
If there is continuity, go to step 7.
¾
If there is no continuity, check that wires to the
terminal block are mechanically secure. If so, replace
the main wire harness and test the dryer.
7. Check for continuity between the neutral (N) terminal of
the plug and P8-3 (white wire) on the CCU.
¾
If there is continuity, go to step 8.
¾
If there is no continuity, and the mechanical
connections of the wire are secure, replace the main
wire harness.
8. Visually check that ALL connectors are fully inserted into
the CCU.
9. Visually check that ALL connectors are fully inserted into
the UI.
10. Reassemble all parts and panels.
11. Plug in dryer or reconnect power.
12. Perform steps under “Install Diagnostics”, page 5-4, to
verify repair.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
Summary of Contents for WED99HEDC0
Page 12: ...1 8 n HybridCare Dryer with Heat Pump Technology GENERAL INFORMATION Notes ...
Page 26: ...2 14 n HybridCare Dryer with Heat Pump Technology OPERATION Notes ...
Page 48: ...3 22 n HybridCare Dryer with Heat Pump Technology INSTALLATION Notes ...
Page 68: ...4 20 n HybridCare Dryer with Heat Pump Technology COMPONENT ACCESS Notes ...
Page 98: ...6 22 n HybridCare Dryer with Heat Pump Technology TESTING Notes ...
Page 100: ...W10764068A HybridCare Duet Dryer with Heat Pump Technology ...