DIAGNOSTICS & TROUBLESHOOTING
HybridCare™ Dryer with Heat Pump Technology
n
5-7
Code Description
Explanation and Recommended Procedure
F4E4
L2 Line Voltage Error
Indicates low L2 voltage (less than 50 V) is detected at the CCU.
• Check to see if a household fuse has blown or a circuit breaker has tripped.
• Confirm the power cord is properly installed and plugged into the power outlet.
• Unplug dryer or disconnect power and check the relay connections on the CCU.
F6E1
F6E2
Communications Error
UI to CCU
Communication Error
CCU to UI
Communication between the CCU and UI has not been detected.
• Unplug dryer or disconnect power.
• Check the harness continuity and connections between the CCU and UI.
• Check AC and DC supplies. See TEST #1: CCU Power Check, page 6-4.
• Replace the User Interface.
• Replace the CCU.
F9E1
Drain System Error
Indicates that the float switch is in full position and the CCU has been in run mode for
60 seconds.
LF
Lint Filter Removed
Indicates that the lint filter has been removed from running position.
• Place the filter back into running position, and verify that it is properly seated.
For Service Technician Use Only
Service Fault/Error Codes
Continued from page 5-7
Summary of Contents for WED99HEDC0
Page 12: ...1 8 n HybridCare Dryer with Heat Pump Technology GENERAL INFORMATION Notes ...
Page 26: ...2 14 n HybridCare Dryer with Heat Pump Technology OPERATION Notes ...
Page 48: ...3 22 n HybridCare Dryer with Heat Pump Technology INSTALLATION Notes ...
Page 68: ...4 20 n HybridCare Dryer with Heat Pump Technology COMPONENT ACCESS Notes ...
Page 98: ...6 22 n HybridCare Dryer with Heat Pump Technology TESTING Notes ...
Page 100: ...W10764068A HybridCare Duet Dryer with Heat Pump Technology ...