4-10
n
HybridCare™ Dryer with Heat Pump Technology
COMPONENT ACCESS
To Remove the Belt and Drum
1.
Unplug dryer or disconnect power.
2.
Remove drain hose from standpipe or laundry tub.
3.
Perform the procedures on page 4-4, “Removing the Top
Panel” and “Removing the Console” prior to performing
the following steps.
4.
Perform the procedures on page 4-7, “Removing the Front
Panel” prior to performing the following steps.
5.
Remove front 1/4” hex-head screw securing the control
bracket to the console bracket...or remove the entire
control bracket (see Figure 1).
Front Control Bracket Screw
Figure 1
6.
Remove the four (4) 1/4” hex-head screws from the
console bracket and remove (see Figure 2).
Console Bracket Screws
Figure 2
Removing the Belt, Drum, and Rollers
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
7.
Disconnect Moisture Sensor connector (see Figure 3).
Moisture Sensor
Connector
Figure 3
8.
Remove two (2) 1/4” hex-head screws securing the Outlet
Grill & Housing Assembly to the front bulkhead (see
Figure 4).
8.
Lift up the lint screen holder/moisture sensor assembly
from the bulkhead (see Figure 3).
Outlet Grill &
Housing Assembly
Remove 2 Hex
Head Screws
Moisture Sensor
M/F Connectors
Figure 4
9.
Remove the four (4) 1/4” hex-head screws from the
secondary lint assembly bezel and remove (see Figure 5).
Remove Screws
Figure 5
Summary of Contents for WED99HEDC0
Page 12: ...1 8 n HybridCare Dryer with Heat Pump Technology GENERAL INFORMATION Notes ...
Page 26: ...2 14 n HybridCare Dryer with Heat Pump Technology OPERATION Notes ...
Page 48: ...3 22 n HybridCare Dryer with Heat Pump Technology INSTALLATION Notes ...
Page 68: ...4 20 n HybridCare Dryer with Heat Pump Technology COMPONENT ACCESS Notes ...
Page 98: ...6 22 n HybridCare Dryer with Heat Pump Technology TESTING Notes ...
Page 100: ...W10764068A HybridCare Duet Dryer with Heat Pump Technology ...