COMPONENT ACCESS
HybridCare™ Dryer with Heat Pump Technology
n
4-3
Component Locations
COMPONENT LOCATIONS — BASE COMPONENTS
3$*(
FOR SERVICE TECHNICIAN’S USE ONLY
DO NOT REMOVE OR DESTROY
COMPONENT LOCATIONS
Figure 10 - Internal components.
SPECIFICATIONS
Voltage:
240 VAC (200-260) Elect. Dryer, 2-phase, “optimized”
208 VAC (176-229) Elect. Dryer, 3-phase, “less optimized”
Amps:
(ELECT) 30 Amp Service
Frequency:
58 to 62 Hz (60 Hz nominal)
Operating Temperature Range:
40 to 105°F (5 to 40°C)
Dryer Height:
39 in. (99.1 cm)
Dryer Width:
27 in. (68.6 cm)
Dryer Depth:
31 in. (78.7 cm)
DRYER SPECIFICATIONS
Condenser
Evaporator
Drain Hose
Drain Pump
Air Blower
Motor
Auxiliary
Fan
Compressor
Motor Capacitors
Float Sw.
Figure 3 - Base Components
Post Condenser