background image

 

 

Machflow hand dryer 

 

 
 

Safety regulations 

 

 

All installation, maintenance and repair tasks must be carried out by qualified 
technicians. 

 

Mediclinics remembers the importance of: 

 

1. Becoming  familiar  with  the  equipment  and  carefully  reading  the  user  manual  prior  to 
operating.  

 

2. Disconnecting power prior to beginning any repair or maintenance action.  

 

3. Exercising care in accordance with the procedures included herein.  

 

 
 

General maintenance 

 
 

Preventive Maintenance - Cleaning 

 

Inspect the units 

annually or quarterly, 

depending on the dryer’s operating cycles.

 

 

Clean the active parts of the unit, such as: the motor, the heating element, the fan and 

the electronic circuit board with a soft brush. 

 

Maintain the air inlet and outlet free of dust and other obstructions; use a soft flat ended 

brush. 

 

Summary of Contents for Machflow

Page 1: ...er prior to beginning any repair or maintenance action 3 Exercising care in accordance with the procedures included herein General maintenance Preventive Maintenance Cleaning Inspect the units annually or quarterly depending on the dryer s operating cycles Clean the active parts of the unit such as the motor the heating element the fan and the electronic circuit board with a soft brush Maintain th...

Page 2: ... of the casing Removal of the casing Using a Machflow security screwdriver release the two screws located at the lower part of the casing Carefully remove the casing trying not to damage the LED viewing screen ...

Page 3: ... 30 000 rpm Class F Maintenance As preventive maintenance we recommend using a soft brush to remove dust and dirt on an annual or bi annual basis depending on the dryer s operating cycles Replacement of the motor Using a Machflow security screwdriver release the two screws located at the lower part of the casing ...

Page 4: ...Carefully remove the casing trying not to damage the LED viewing screen Use a Phillips head screwdriver to remove the four screws in the upper nozzle ...

Page 5: ...the upper nozzle If the nozzle is difficult to remove use a flathead screwdriver to help extract it taking care not to damage the plastic parts Once the motor is visible remove the two terminals from the motor ...

Page 6: ...Remove the motor and replace it To fit the new motor follow the steps above in reverse order ...

Page 7: ...soft brush to remove dust and dirt on an annual or bi annual basis depending on the dryer s operating cycles It is also recommended to clean the LEDs regularly using a cloth dampened with alcohol to ensure the signal is emitted and received properly Replacement of the electronic circuit board Using a Machflow security screwdriver release the two screws located at the lower part of the casing ...

Page 8: ...Carefully remove the casing trying not to damage the LED viewing screen Unscrew the power supply cables from the electronic circuit board ...

Page 9: ... Remove the ties that secure the cables to the base with the help of cutting pliers With a flat screwdriver remove the Nylon screw that fixes the electronic circuit board to the base ...

Page 10: ...Carefully remove the electronic circuit board trying not to damage the cables Once the electronic circuit board is out of its housing unscrew the two motor cables connected to the terminal block ...

Page 11: ...To fit the new electronic circuit board follow the steps above in reverse order ...