1. Unplug air conditioner or disconnect power.
2. Remove the cabinet from the unit (see
page 4-2 for the procedure).
3. Remove the components cover (see
page 4-5 for the procedure).
REMOVING THE HIGH & LOW WATER LEVEL SWITCHES
High & Low Water
Level Switches
4. Remove the three screws from the water
level switch mounting plate and remove
the plate and switches (see the top right
photo).
5. Loosen the nut from the water level switch
you are servicing, and slide the switch
off the plate.
IMPORTANT NOTE:
Make
sure that you position the rubber seal on
the switch so it is between the bottom of
the nut and the top of the mounting plate
when you install the switch.
3 Screws
Mounting Plate
Nut
Seal
Nut
High Water
Level Switch
Low Water
Level Switch
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.