m
2000D
technical manual
Page 41
S
INGLE
DLC
S
LAVE
C
ONNECTION
The diagram below demonstrates a typical wiring diagram of load cells to the slave DLC
and the DLC slave to the M2000D indicator:
DLC LINK
5
CTL-
4
CTL+
3
SHL
2
V-
1
V+
M2000D INDICATOR
1
CTL-
2
CTL+
3
4
V-
5
V+
DLC SLAVE
1
- EXC
2
+EXC
3
SHLD
4
- SIG
5
+SIG
- EXC
1
+EXC
2
SHLD
3
- SIG
4
+SIG
5
1
- EXC
2
+EXC
3
SHLD
4
- SIG
5
+SIG
- EXC
1
+EXC
2
SHLD
3
- SIG
4
+SIG
5
1
- EXC
2
+EXC
3
SHLD
4
- SIG
5
+SIG
- EXC
1
+EXC
2
SHLD
3
- SIG
4
+SIG
5
1
- EXC
2
+EXC
3
SHLD
4
- SIG
5
+SIG
- EXC
1
+EXC
2
SHLD
3
- SIG
4
+SIG
5
CORNER2
CORNER1
CORNER4
CORNER3
CORNER6
CORNER5
CORNER8
CORNER7
DLC LINK
GENERAL CABLE
CONNECTIONS