m
2000D
technical manual
Page 29
532 Auto Corner Span Adjustment: calibration command
This command allows the field personnel to adjust for small linearity discrepancies on a
corner or section basis for a hopper or sectional scales. This command serves the same
purpose as command
531
but instead of adjusting weight in a manual way, we simply type
in the weight and the system will automatically span the selected corner/section to the
target weight.
This command will act on the currently selected corner or section as outlined in the status
display. The instructions below outline the steps for corner/section adjustments:
q
Before executing this command, use the [TARE] key to select the corner / section to be
adjusted for span corrections.
q
Use the [ON/OFF] key to display graduated weight counts before executing the
command – display prefixed with a flashing letter ‘
C
’.
q
Place a reference weight on the corner/section to be adjusted.
q
Execute command 532 followed by [PRINT/SELECT], the display will flash the
currently selected corner/section to be adjusted – press [PRINT/SELECT] again to
confirm the corner to be adjusted or [CLEAR] to abort the command.
q
Enter the value of the weight currently on the scale (gross) followed by pressing the
[TARE] key. Once the user pressed [TARE] the adjustment to the target weight will
take place.
This command remembers the last weight entered, so the user can just press
the [TARE] key in stead of repeatedly having to enter the weight value.
If you are not happy with the correction you can clear it using command 530, please see
command 530 for details.
Command 530 clears all correction entries for all section and
corners.
While the adjustment is in progress the following information will be displayed as shown
in the example below:
Channel Status Information
A –
This field will flash while in Corner / Section Adjustment mode
GENERAL DLC