m
2000D
technical manual
Page 21
HOPPER SCALE
-
This scale allocation is a 4
Ch
annel
H
opper
scale consisting of 4 corners on the
P
rimary DLC
Œ
corner
1
goes to
cell 1
on the
P
rimary DLC terminal box
•
corner
2
goes to
cell 2
on the
P
rimary DLC terminal box
Ž
corner
3
goes to
cell 3
on the
P
rimary DLC terminal box
•
corner
4
goes to
cell 5
on the
P
rimary DLC terminal box
(In this example cell 4 was disabled due to damage)
H
OPPER
E
XAMPLE
(1)
Once the 4-corner hopper scale is allocated (in calibration mode), the allocation
information pertaining to each corner of the hopper scale can be viewed as follows by
pressing the [TARE] key while in calibration mode:
DLC (P)
RIMARY
DLC (S)
ECONDARY
NOTE:
At any time the user can press the [ON/OFF] key to view the raw counts
related to the corner in question.
Œ•Ž••
NOTE:
As illustrated in this example the user
can disable a cell that is damaged. Please see
calibration command 525 on how to disable cells.
Disabling cells should be done before assigning
the scale.
HOPPER SCALE
INSTALLATIONS