m
2000D
technical manual
Page 47
Error Messages
1 Invalid parameter number for calibration mode
2
Graduation size invalid
3
Decimal Position Invalid
4
Flag values must be 1 for ‘ON’ and 0 for ‘OFF’
5
Push to Zero Window must be 0-99
6
Zero tracking must be 1-99 or 100, 200, 300.
7
Only 1 will reset parameters
8
Only 1 will reset span table
9
Span exceeds maximum capacity or span too small
10
IZSM value can be 1 for ON and 0 for OFF
11
Test Weight units must be 0=lb or 1=kg.
12 Motion settle time out of range 1-100
13 Power on units may only be 0=lb, 1=kg.
14 Invalid Time entry HH.MM.SS
15 Invalid Date entry YY.MM.DD
16 Motion value is out of range
17 Press tare to increment span table, any other key invalid
18 Press tare to decrement span table, any other key invalid
19
Span table cannot be decremented past 1
20
Parameter memory write error, indicator requires service
21
Parameter checksum error, parameters have been lost.
22
Program check fault, indicator requires service
23
Invalid Serial Port speed setting
24
Invalid Serial Port Parity parameter
25
Cannot increment Span Table any further
26
Entered offset larger than Capacity
27
Invalid String mode for com port
28
Power on Zero warning 0=Off, 1=On
29
Channel enable is 0=Off and 1=On
30
Only 1 will set the deadload
31
Sound Volume can be between 0-3
32
Keypress feedback can be 0=OFF or 1=ON
33
Invalid Com String mode parameter
34
Invalid Com Port Interface value
35
*
36
*
37
Channel 1 cannot be disabled
38
Invalid Print Select Function Number
39
*
40
Scale channel is not enabled
41
Pushbutton Tare is invalid (Over, Motion,or disabled)
42
Keyboard tare available on channel 1 only
43
Tare greater than capacity
44
Invalid Password number range, can only be 0000-9999.
45
Only a value of 0, 1 or 80 is accepted as a parameter