8
UM380 03 010
InterChange iQ 2000 and iQ 2000plus
Caution:
The Interchange iQ 2000 and iQ 2000plus must be earthed at all times via the protective
earth terminal on the rear of the unit.
The earthing cable must conform to the following specification. It shall:
•
be PVC covered green with yellow longitudinal coloured stripes as defined in
EN 60950,
•
be rated at 17 amps,
•
have a cross sectional area of 1.5mm
2
,
•
be of stranded wire 7/0.53, and
•
be terminated with an M3 ring terminal 1-2.6 mm
2
conductor.
100 -240 VAC
50 - 60Hz
350mA
FUSE
T2A H 250V
Protective Earth
Figure 5: View showing earth screw on the rear panel.
Location of Unit
Make sure that there is free flow of air between the base of the unit and the surface on which
it is installed.
Connecting to Power
Make sure the mains switch on the mains inlet panel at the rear of the unit is set to the
OFF
(
O
) position.
Use the power cable provided to connect between the mains inlet and the designated line
distribution socket.