Quick Parameter Reference
.
16 | CTW900
Param.
Function
Adjustable Range
Factory
Setting
User’s
Setting
Proper.
Groups
Page
25 = Trace Function
P0267
DI5 Function
See options in P0266
14
CFG1
31, 34
91
P0268
DI6 Function
See options in P0266
10
CFG1
31, 34
91
P0269
DI7 Function
See options in P0263
0
CFG1
34
91
P0270
DI8 Function
See options in P0263
0
CFG1
34
91
P0275
DO1 Function (RL1)
0 = Not Used
13
CFG1
35
97
1 = N* > Nx
2 = N > Nx
3 = N < Ny
4 = N = N*
5 = Zero Speed
6 = Ia > Ix
7 = Ia < Ix
8 = Torque > Tx
9 = Torque < Tx
10 = Remote
11 = Run
12 = Ready
13 = Without Fault
14 = With F003
15 = With F072
16 = With F077
17 = 4-20mA OK
18 = P0695 Value
19 = Forward
20 = With Fault
21 = Time Enab > Hx
22 = SoftPLC
23 = N>Nx/Nt>Nx
24 = Without Alarm
25 = Without Alarm/ Fault
26 = Bridge A Conducting
P0276
DO2 Function (RL2)
See options in P0275
2
CFG1
35
97
P0277
DO3 Function (RL3)
See options in P0275
1
CFG1
35
97
P0278
DO4 Function
See options in P0275
0
CFG1
35
97
P0279
DO5 Function
See options in P0275
0
CFG1
35
97
P0287
Nx/Ny Hysteresis
0 to 900 rpm
18 rpm
35
101
P0288
Nx Speed
0 to 10000 rpm
120 rpm
35
101
P0289
Ny Speed
0 to 10000 rpm
1800 rpm
35
101
P0290
Ix Current
0 to 1.25x I
rat
1.0x I
rat
35
102
P0291
Zero Speed Zone
0 to 10000 rpm
18 rpm
30, 35
82
P0292
N = N* Band
0 to 10000 rpm
18 rpm
35
102
P0293
Tx Torque
0 to 1000 %
100 %
35
102
P0294
Hx Time
0 to 6553 h
4320 h
35
102
P0295
Drive Rated Current
0 = 20 A
RO
09, 36
104
1 = 50 A
2 = 90 A
3 = 125 A
4 = 180 A
5 = 260 A
6 = 480 A
7 = 640 A
8 = 1000 A