Installation and Connection
CTW900 | 37
Dimension
Model
A
B
C
mm
(in)
mm
(in)
mm
(in)
Size A
60
30
100
(2,36)
(1,18)
(3,94)
Size B
100
30
130
(3,94)
(1,18)
(5,12)
Size C
100
100
130
(3,94)
(3,94)
(5,12)
Size D
300
100
300
(11,81)
(3,94)
(11,81)
Figure 5.1
– Necessary clearances for ventilation of the converter
Dimension
Fastening
Screw
Weight
Model
L
H
P
a
b
mm
(in)
mm
(in)
mm
(in)
mm
(in)
mm
(in)
Size A
276
420
244
225
400
M6
13 Kg
(10,8)
(16,5)
(9,6)
(8,9)
(15,7)
Size B
275
420
300
225
400
M6
20 Kg
(10,8)
(16,5)
(11,8)
(8,9)
(15,7)
Size C
277
650
428
225
625
M8
47 Kg
(10,9)
(25,5)
(16,8)
(8,9)
(24,6)
Size D
650
1285
427
450
1225
M10
150 Kg
(25,5)
(50,5)
(16,8)
(17,7)
(48,2)
Figure 5.2
– Main measures for mechanical installation