Detailed Description of the Parameters
.
CTW900 | 119
P0561 – CH1: Channel 1 of Trace
P0562 – CH2: Channel 2 of Trace
P0563 – CH3: Channel 3 of Trace
P0564 – CH4: Channel 4 of Trace
Adjustable Range:
0 = Inactive
Factory Setting:
P0561 = 1
1 = Total Reference
P0562 = 2
2 = Present Speed
P0563 = 3
3 = Armature Current
P0564 = 0
4 = Armature Voltage
5 = Field Current
6 = Motor Torque
7 = AI1
8 = AI2
9 = AI3
10 = AI4
Properties:
Groups of
01 PARAMETER GROUPS
Access via HMI:
41 Trace Function
........
Description:
They select the signals that will be recorded on channels 1 to 4 of the Trace function.
The options for these parameters are the same as those presented in P0550. By selecting the option “Inactive”,
the total memory available for the Trace function is distributed among the other active channels.
P0571 – Start Trace
Adjustable Range:
0 = Inactive
Factory Setting:
0
1 = Active
Properties:
Groups of
01 PARAMETER GROUPS
Access via HMI
:
41 Trace Function
........
Description:
It starts the waiting for the trigger of the Trace function.
Since this is a parameter that can be changed with the converter running, it is not necessary to press “Save” on
the keypad for the waiting for the trigger to start.
Notes:
■
This parameter has no effect if there are no active channels, or if there is no available memory for the Trace
function (P0560 = 0).
■
P0571 returns automatically to 0, for safety, in case any of the parameters between P0550 and P0564 is
changed.
P0572 – Day/ Month of the Trace Trigger
Adjustable Range:
00/00 to 31/12
Factory Setting:
P0573 – Year of the Trace Trigger
Adjustable Range:
00 to 99
Factory Setting:
P0574 – Hour of the Trace Trigger
Adjustable Range:
00:00 to 23:59
Factory Setting: