EN
36
Light Array Operation
5.4.3 Functions
Receiver 1
Receiver 2
Effect on common output
Restart Inhibit
activated
Must be acknowledged after penetration into safety
field 1/2.
activated
Must be acknowledged after penetration into safety
field 2.
activated
activated
Not reasonable, because an interferrence of safety
field 2 has to be acknowledged twice.
Contactor Monitoring
activated
Downstreamed contactor of receiver 1 is controlled.
activated
Monitoring of the downstreamed contactor not
possible.
Fix Blanking
Reduced Resolution
activated
Acts upon common output. The function affects
safety field 1 only. Connection of an external warn-
ing indicator lamp isn‘t possible.
activated
Acts upon common output. The function affects
safety field 2 only. Connection of an external warn-
ing indicator lamp isn‘t possible.
activated
activated
Acts upon common output. The function affects
both safety fields, but the warning indicator lamp
does not indicate the status of safety field 1.
Connector Pin Assignments for Safety Operation with Cascading
Required system components:
2 × transmitters, 2 × receivers
1 × connector cable for transmitter
1 × connector cable for receiver
1 × connector cable
From
To
Transmitter Wiring
Pin 1
24 V DC
24 V DC supply voltage
Pin 2
Unused
Pin 3
0 V
0 V supply voltage
Pin 4
Earth/shield
Operational earth
Receiver Wiring
Pin 1
Signal output
Muting indicator muting terminal
Pin 2
24 V DC
4 V DC supply voltage
Pin 3
OSSD1 output
PLC or relay
Pin 4
Acknowledge
Free
Pin 5
Contactor monitor
Free
Pin 6
OSSD2 output
PLC or relay
Pin 7
0 V
0 V supply voltage
Pin 8
Earth/shield
Operational earth
Connector cable from socket 2 at receiver 1 to socket 1 at receiver 2
Connector cable from socket 4 at transmitter 1 to socket 3 at transmitter 2