EN
32
Light Array Operation
From
To
Transmitter Wiring
Pin 1
24 V DC
24 V DC supply voltage
Pin 2
Unused
Pin 3
0 V
0 V supply voltage
Pin 4
Earth/shield
Operational earth
Receiver Wiring
Pin 1
Signal output
Muting indicator muting terminal
Pin 2
24 V DC
24 V DC supply voltage
Pin 3
OSSD1 output
PLC or relay
Pin 4
Acknowledge
Free
Pin 5
Contactor monitor
Free
Pin 6
OSSD2 output
PLC or relay
Pin 7
0 V
0 V supply voltage
Pin 8
Earth/shield
Operational earth
5.3.0.7 Reduced Resolution Procedure
Start
Repeatedly move the
object through the
safety field
The number of blanked beams
appears at the display,
and the blanking LED blinks
Press the enter key
on the receiver
Does 00
appear at the display
and does the failure
LED blink?
The light barrier
boots and enables
the outputs
The Safety Light Array
is ready for operation
Display at Receiver
Serial Communication
Cascading
Timing
Restart Inhibit
8
7
6
5
4
3
2
1
ON OFF
Contactor Monitoring
Reduced Resolution
Fix Blanking
S1
Reduced Resolution
Operating Mode
DIP Switch Settings: Receiver
Set the
reduced resolution
DIP switch
no
1. Remove the object from the
safety field
2. Reset the reduced resolution
DIP switch
3. Switch the light barrier on and off
Starting with the pilot
beam, move the
test rod through the
safety field
Does the
total number of all
beams appear at
the display?
no