Light Array Operation
From
To
Transmitter Wiring
Pin 1
24 V DC
24 V DC supply voltage
Pin 2
Unused
Pin 3
0 V
0 V supply voltage
Pin 4
Earth/shield
Operational earth
Receiver Wiring
Pin 1
Signal output
Free
Pin 2
24 V DC
24 V DC supply voltage
Pin 3
OSSD1 output
PLC or relay
Pin 4
Acknowledge
Pushbutton (normally open), 24 V DC
Pin 5
Contactor monitor
Free
Pin 6
OSSD2 output
PLC or relay
Pin 7
0 V
0 V supply voltage
Pin 8
Earth/shield
Operational earth
Setup Procedure
If the function type is combined with an operating mode, the operating mode must first be set up. The Start-Up
inhibit (restart inhibit) function is then activated by appropriately setting the restart inhibit DIP switch.
DIP Switch Settings: Receiver
Serial Communication
Cascading
Timing
Restart Inhibit
8
7
6
5
4
3
2
1
ON OFF
Contactor Monitoring
Reduced Resolution
Fix Blanking
S1
Display at Receiver
Function Mode:
Restart Inhibit