![Wenglor SB4-I Operating Instructions Manual Download Page 31](http://html1.mh-extra.com/html/wenglor/sb4-i/sb4-i_operating-instructions-manual_956893031.webp)
31
Safety Light Array
Number of muted beams
Resolution d of the test object
0 (full resolution)
30 mm
1
47 mm
2
64 mm
3
81 mm
4
98 mm
Schematic Diagram, Reduced Resolution
8) Serial Communication
7) Timing
6) Cascading
5) Reduced Resolution
3) Fix Blanking
2) Contactor Monitoring
1) Restart Inhibit
8) Serial Communication
7) Timing
6) Cascading
5) Reduced Resolution
3) Fix Blanking
2) Contactor Monitoring
1) Restart Inhibit
88
2
89
Receiver
Control Panel
Emitter
Control Panel
Socket
Socket
Plug
Plug
Failure (RD)
Normal
Operation (GN)
Enter Button
Enter Button
Failure (RD)
Display 2
Display 1
Blanking
Alignment (YE)
OSSD off (RD)
OSSD on (GN)
Dip-Switch S1
Signal Output
2
1
3
4
4
2
6
1
3
5
7
8
24 V
Plug Receiver
Contactor Monitoring
Acknowledge
OSSD 1
24 V
Safety PLC
(Cat. 4; PL e; SIL3)
or Safety Relay
24 V
OSSD 2
0 V
Earth/Shield
0 V
Plug Emitter
Earth/Shield
Connector Pin Assignments for Safety Operation with Reduce Resolution
Required system components:
1 × transmitter, 1 × receiver
1 × connector cable for transmitter
1 × connector cable for receiver