background image

12

13

06.05.2022

EN

EN

• 

materials that cannot be removed must be 

secured against e.g. welding spatter by covering 

them with e.g. metal sheets, drywall, etc.;

• 

check  if  materials  or  flammable  objects 

in surrounding rooms require protection;

• 

seal 

with 

non-flammable 

materials 

any 

openings in installation, ventilation, 

etc. located near the place of work;

• 

secure electric cables, gas or installation 

pipes  covered  with  flammable  insulation 

against welding spatter if they are within the 

range  of  work  that  constitutes  a  fire  hazard;

• 

check that the planned work will not be carried 

out  in  rooms  that  were  painted  using  flammable 

substances  or  where  other  flammable  substances 

were used on the day of planned work.

SPARKS MAY CAUSE A FIRE

Sparks  produced  by  welding  can  cause  fires,  explosions 

and burns on exposed skin. During welding, it is necessary 

to wear welding gloves and protective clothing. Remove or 

secure any flammable materials and substances from the 

place of work. Do not weld sealed containers or tanks in 

which  flammable  liquids  were  stored.  Such  containers  or 

tanks must be rinsed before welding to remove flammable 

liquids.  Do  not  weld  in  the  vicinity  of  flammable  gas, 

vapours or liquids. Fire equipment (blankets, dry powder 

extinguisher or extinguishing foam) must be placed near 

the workplace in an easily visible and reachable place. 

A CYLINDER MAY EXPLODE

Use only approved gas cylinders and a properly working 

reducer. The cylinder should be transported, stored and 

placed in a vertical position. Protect the cylinders from heat 

sources, tipping over and mechanical damage. Maintain all 

gas installation elements: cylinder, hose, fittings, reducer in 

good condition.

WELDED MATERIALS CAN CAUSE BURNS

Never touch the welded components with parts of your 

body without protection. When touching and moving 

welded material, always use welding gloves and tongs.

3.3. PREPARATION OF WELDING WORK SITE

WELDING OPERATIONS MAY CAUSE FIRE OR 

EXPLOSION!

• 

Strictly follow the occupational health and safety 

regulations applicable to welding operations and 

make sure to provide appropriate fire extinguishers 

at the welding work site.

• 

Never  carry  out  welding  operations  in  flammable 

places that pose the risk of material ignition.

• 

It is prohibited to weld in the presence of an 

explosive mixture of combustible gases, vapours, 

mists or dust with air.

• 

Remove  all  flammable  materials  within  12  meters 

from the welding operations site and if removal is 

not  possible,  cover  flammable  materials  with  fire 

retardant covering.

• 

Use safety measures against sparks and glowing 

metal particles.

• 

Make sure that sparks or hot metal splinters do 

not penetrate through the slots or openings in the 

coverings, shields or protective screens.

• 

Do not weld tanks or barrels that contain or have 

contained flammable substances. Do not weld in the 

vicinity of such containers and barrels.

• 

Do not weld pressure vessels, pipes of pressurised 

installations or pressure trays.

• 

Always ensure adequate ventilation.

• 

It is recommended to take a stable position prior to 

welding.

3.4. PERSONAL PROTECTION EQUIPMENT

ELECTRIC ARC RADIATION CAN CAUSE DAMAGE TO 

EYES AND SKIN!

• 

When welding, wear clean, oil stain free protective 

clothing made of non-flammable and nonconductive 

materials (leather, thick cotton), leather gloves, high 

boots and protective hood.

• 

Before  welding  remove  all  flammable  or  explosive 

items, such as propane butane lighters or matches.

• 

Use facial protection (helmet or shield) and eye 

protection,  with  a  filter  featuring  a  shade  level 

matching the sight of the welder and the welding 

current. The safety standards suggest colouring 

No. 9 (minimum No. 8) for each current below 300 

A. A lower shield colouring can be used if the arc is 

covered by the workpiece.

• 

Always use approved safety glasses with side 

protection under the helmet or any other cover. 

Use guards for the welding operation sites in order 

to protect other people from the blinding light 

radiation or projections.

• 

Always wear earplugs or another hearing protection 

to protect against excessive noise and to avoid 

spatter entering the ears.

• 

Bystanders should be warned to not look at the arc.

3.5. PROTECTION AGAINST ELECTRIC SHOCK

ELECTRIC SHOCK CAN BE LETHAL!

• 

The power cable must be connected to the nearest 

socket and placed in a practical and secure position. 

Positioning the cable negligently in the room and on 

a surface which was not checked must be avoided, as 

it can lead to electrocution or fire.

• 

Touching electrically charged elements can cause 

electrocution or serious burns.

• 

The electrical arc and the working area are electrically 

charged during the power flow.

• 

The device’s input circuit and inner power circuit are 

also under voltage charge when the power supply 

is turned on.

• 

The elements under the voltage charge must not be 

touched.

• 

Dry, insulated gloves without any holes and 

protective clothing must be worn at all times.

• 

Insulation mats or other insulation layers, big enough 

as not to allow for body contact with an object or the 

floor, must be placed on the floor.

• 

The electrical arc must not be touched.

• 

Electrical power must be shut down prior to cleaning 

or electrode replacement.

• 

It must be checked if the earthing cable is properly 

connected or the pin is correctly connected to the 

earthed socket. Incorrectly connecting the earthing 

can cause life or health hazard.

• 

The power cables must be regularly checked for 

damage or lack of insulation. Damaged cables must 

be replaced. Negligent insulation repair can cause 

death or serious injury.

• 

The device must be turned off when it is not in use.

• 

The cable mustn’t be wrapped around the body.

• 

A welded object must be properly grounded.

• 

Only equipment in good condition can be used.

• 

Damaged device elements must be repaired or 

replaced. Safety belts must be used when working 

at height.

• 

All  fittings  and  safety  elements  must  be  stored  in 

one place.

• 

From the moment of turning on the release, the 

handle end must be kept away from the body.

• 

The chassis ground must be mounted to the welded 

element or as close to it as possible (e.g. to a work 

table).

THE DEVICE CAN STILL BE UNDER VOLTAGE UPON 

FEEDER DISCONNECTION!

• 

The voltage in the input capacitor must be checked 

upon  turning  off  the  device  and  disconnecting  it 

from the power source. One must make sure that the 

voltage value is equal to zero. Otherwise, the device 

elements must not be touched.

3.6. GASES AND FUMES

PLEASE NOTE! GAS MAY BE LETHAL OR DANGEROUS 

TO HUMAN HEALTH!

• 

Always keep a certain distance from the gas outlet 

• 

When welding, ensure good ventilation. Avoid 

inhaling the gas.

• 

Chemical substances (lubricants, solvents) must be 

removed from the surfaces of welded objects as they 

burn and emit toxic smokes under the influence of 

temperature.

• 

The welding of galvanised objects is permitted only 

when efficient ventilation is provided with filtration 

and access to fresh air. Zinc fumes are very toxic, an 

intoxication symptom is the so-called zinc fever.

4. OPERATION

4.1. GENERAL NOTES

• 

The device must be applied according to its purpose, 

with observance of OHS regulations and restrictions 

resulting from data included in the rating plate (IP 

level, operation cycle, supply voltage, etc.).

• 

The machine must not be opened as it will cause 

warranty loss and, in addition, exploding. Unshielded 

elements can cause serious injuries.

• 

The producer does not bear any responsibility for 

technical changes in the device or material losses 

caused by the introduction of the said changes.

• 

In case of incorrect device operation, contact the 

service centre.

• 

Louvers must not be shielded – the welder must 

be  positioned  at  30  cm  distance  from  the  objects 

surrounding it.

• 

The welder must not be kept under your arm or near 

your body.

• 

The machine must not be installed in rooms with 

aggressive environments, high dustiness and near 

devices with high electromagnetic field emission.

• 

Do not fill the radiator with unsuitable liquids. Use 

clean water free of contaminants.

• 

The water in the radiator should be regularly checked 

and replaced in order to avoid accumulation of 

contaminants that may cause damage to the 

radiator and the welder with accessories.

• 

If the device is used at a temperature of <10 ° C, 

an anti-freeze agent should be added to the liquid. 

Glycol-based agents are recommended for the 

purpose. Do not use agents containing propylene.

• 

Insufficient amount of liquid in the radiator tank can 

damage the pump. Always make sure that the water 

level is above the minimum.

• 

When topping up the radiator with water, take extra 

care not to flood the connection sockets and (in the 

case of ENTRIX 315 AW) the welder.

4.2. DEVICE STORAGE

• 

The machine must be protected against water and 

moisture.

• 

The welder must not be positioned on heated 

surfaces.

• 

The device must be stored in a dry and clean room.

4.3 CONNECTING THE DEVICE

4.3.1 CONNECTING THE POWER

• 

The connection of the device must be performer by 

a qualified person. In addition, a person with required 

qualifications should check if the earthing or electrical 

installation with protection system is in line with the 

safety regulations and if they operate correctly.

• 

The device must be placed near the work station. 

• 

Connecting excessively long conduits to the machine 

must be avoided.

• 

One-phase welders should be connected to the 

socket fitted with an earthing prong.

• 

Welders powered from a 3-Phase network are 

delivered without a plug, the plug must be obtained 

independently and installation should be assigned to 

a qualified person.

PLEASE NOTE! THE DEVICE MAY ONLY BE USED UPON 

CONNECTION TO AN INSTALLMENT WITH A PROPERLY 

FUNCTIONING FUSE.

4.3.2 CONNECTING GAS

• 

Gas tanks must be placed far from the welded object 

and be protected against falling.

• 

Gas connector of the welder must be connected with 

the tank or gas installation by means of the correct 

pipe and regulator with gas flow regulation. Please 

note! Connection of line regulators to the tank and 

the other way round is prohibited. Such a change can 

result in regulator damage and serious injuries.

• 

Economical gas use extends the welding time.

5. DEVICE USE

ENTRIX 315A

10 9 8 7

6

4

3

5

1

2

Summary of Contents for ENTRIX 315A

Page 1: ...ALUMINIUM WELDER BEDIENUNGSANLEITUNG User manual N vod k pou it Manuel d utilisation Istruzioni per l uso Manual de instrucciones EXPONDO COM ENTRIX 315A ENTRIX 315AW...

Page 2: ...ent higher than 150 A connect it to the radiator Welding with a current higher than 150 A without cooling may cause permanent damage to the device and accessories UPOZORN N Pokud pou v te sv e ku se s...

Page 3: ...ung von Elektro Gas und Installationskabeln mit brennbarer Isolierung sofern sie sich im Gefahrenbereich des Feuerwerks befinden berpr fen ob an diesem Tag am Ort der geplanten Arbeiten keine Farbanst...

Page 4: ...n hohe Abgaswerte oder viel Staub auftreten Auch in R umen in denen sich Ger te befinden die hohe Werte elektromagnetischer Emissionen aufweisen sollte das Schwei ger t nicht verwendet werden Verwende...

Page 5: ...nd die Diode I leuchtet W hlen Sie mit dem Drehknopf N den gew nschten Parameter aus der Speicherposition und dr cken Sie dann erneut die Men taste J die Diode I erlischt die Parameter wurden geladen...

Page 6: ...ifting height m 30 35 Dimensions mm 560x245 x585 920x430 x1130 Weight kg 74 56 without radiator U S E R M A N U A L The operation manual must be read carefully The product must be recycled Satisfies r...

Page 7: ...enough as not to allow for body contact with an object or the floor must be placed on the floor The electrical arc must not be touched Electrical power must be shut down prior to cleaning or electrod...

Page 8: ...or rough adjustment O Pulse No Pulse mode switch P LED P1 Pulse mode P2 No Pulse mode Q AC DC switch R LED R1 AC mode R2 DC mode 5 1 PREPARING THE DEVICE FOR USE DEVICE USE Each unit is equipped with...

Page 9: ...the device If relevant a picture of the damaged broken or defective part It will be easier for your customer service clerk to determine the source of the problem if you give a detailed and precise des...

Page 10: ...ou st kter jsou pod nap t m Pou vejte such ned rav izolovan rukavice a ochrann od v Pou vejte podlahov izola n podlo ky nebo jin izola n materi ly kter jsou dostate n velk aby zabr nily kontaktu t la...

Page 11: ...ky 14 V vod vody 15 V stupn z suvka chlad c jednotky 16 Vstupn z suvka chlad c jednotky 17 P vod vody do chlad c jednotky 18 Nap jec kabel chlad c jednotky POPIS OVL DAC HO PANELU OBA MODELY A P ep na...

Page 12: ...to mo n m podrobn j informace t m rychlej e en probl mu VAROV N Nikdy neotv rejte za zen bez konzultace se servisn m st ediskem M e to v st ke ztr t z ruky Nom du produit Valeur des param tres Nom du...

Page 13: ...uissante ou de toute projection effervescente Il faut galement toujours porter des bouchons pour oreilles boules quies ou autre protection auriculaire afin de se prot ger soi m me contre le niveau son...

Page 14: ...du r servoir d eau du radiateur 18 C ble d alimentation du radiateur DESCRIPTION DU PANNEAU DE COMMANDE LES DEUX MOD LES A Commutateur de mode de travail MMA TIG B Diode B1 Mode MMA actif B2 Mode TIG...

Page 15: ...iser la touche Menu G ou J pour passer de gauche droite entre les param tres r glez les valeurs des param tres avec le bouton N Pour sauvegarder les param tres s lectionn s dans la m moire de l appare...

Page 16: ...ra o altri lavori con utilizzo di sostanze infiammabili LE SCINTILLE POSSONO CAUSARE UN INCENDIO Le scintille generate durante la saldatura possono causare incendi esplosioni e bruciature della pelle...

Page 17: ...toccate 3 6 GAS E FUMO ATTENZIONE IL GAS PU ESSERE PERICOLOSO PER LA SALUTE O CONDURRE ADDIRITTURA ALLA MORTE Tenere sempre una certa distanza dal punto di scarico del gas Garantire una buona ventilaz...

Page 18: ...ro spegnere l unit portando il pulsante On Off 11 in posizione Off e scollegare l unit dalla fonte di alimentazione Istruzioni per l uso La temperatura ambiente non deve superare i 40 C e l umidit rel...

Page 19: ...a que cubra todo el cuerpo Utilice guantes de seguridad Utilice siempre gafas de protecci n Utilice zapatos de seguridad Superficie caliente riesgo de quemaduras Riesgo de explosi n y fuego Vapores no...

Page 20: ...o y la zona de trabajo est n cargados de corriente El circuito de alimentaci n y los circuitos internos de la m quina tambi n tienen tensi n cuando la alimentaci n est encendida No toque piezas el ctr...

Page 21: ...se Frequency frecuencia de pulsos durante la soldadura AC Balance balance de corriente AC AC Frequency frecuencia de corriente AC Down Slope tiempo de descenso de intensidad de corriente End Amps valo...

Page 22: ...gno 5 y girar la clavija del cable para proteger la conexi n 3 Posteriormente conectar el cable de soldeo TIG a la conexi n marcada con el signo 2 y girar la clavija del cable para proteger la conexi...

Page 23: ...odelo N mero de serie A o de producci n Fabricante NAMEPLATE TRANSLATIONS B1 B2 A C D K M1 M2 L N O Q P1 P2 R1 R2 J I G H E F BEDIENFELDES CONTROL PANEL OVL DAC HO PANEL PANNEAU DE COMMANDE PANNELLO D...

Page 24: ...46 47 06 05 2022 NOTES NOTIZEN NOTES NOTIZEN...

Page 25: ...nen Altger te aus privaten Haushalten ihres Gebietes f r Sie kostenfrei entgegengenommen werden M glicherweise holen die rechtlichen Entsorgungstr ger die Altger te auch bei den privaten Haushalten ab...

Reviews: