- 26 -
Index
Function
Access
Data type
Description
0x02
System Command
Write only UIntegerT(8)
Execution of system commands
0x0C
Device Access Locks
Read/write RecordT
Standardized device protection func-
tion
0x10
Vendor Name
Read only
StringT
Manufacturer name
0x11
Vendor Text
Read only
StringT
Manufacturer text
0x12
Product Name
Read only
StringT
Product name
0x13
Product ID
Read only
StringT
Product ID
0x14
Product Text
Read only
StringT
Product text
0x15
Serial Number
Read only
StringT
Serial number
0x16
Hardware Revision
Read only
StringT
Hardware revision
0x17
Firmware Revision
Read only
StringT
Firmware revision
0x20
Error Count
Read only
UIntegerT(16)
Number of errors since the start or re-
set of the gripping module
0x24
Device Status
Read only
UIntegerT(8)
Device status
0x25
Detailed Device Status
Read only
ArrayT of Oc-
tetStringT3
Detailed device status
Table 10: Standardized process parameters
8.2.3
Device-specific Acyclic Process Parameters
Configuration and diagnosis of the gripping module are performed via device-specific acyclic process param-
eters. You can find an overview on the parameters in chapter 12.
8.2.3.1
Motion Parameters
Override Gripping Speed in Percent
Decreases or increases the gripping speed, which has been automatically calculated from the specified
gripping force. The necessary gripping speed is automatically determined by the gripping module and is
optimized for a hard grip (steel on steel), see chapter 5.1.2. This predefined value is equivalent to 100%.
The set value is valid for all grips.
Damage to the gripping module and to the gripped part possible. Excessive gripping speed can
lead to rebound effects and heightened force peaks (gripping impulse) during gripping.
Uneven movement (“clattering”) possible when gripping speed is insufficient.