- 21 -
8
Interface Description IO-Link
The interface description of the IO-Link interface is defined in the IO-Link Device Description (IODD) file that
belongs to the gripping module. The IODD file that is needed for the configuration of the gripping module
can be found on our website at
https://www.weiss-robotics.com/crg
8.1
Cyclic Process Data
Please pay attention to the byte order. According to the IO-Link standard, data is transmitted in big-
endian format.
8.1.1
Output Data (IO-Link Master to Gripping Module)
Table 8 describes the cyclic process data (2 byte) that the gripping module expects from the IO-Link master.
BYTE 0
15
14
13
12
11
10
9
8
VIS
RES
HOME
EN
CMD
BYTE 1
7
6
5
4
3
2
1
0
INDEX
Table 8: Process data word IO-Link master to gripping module