DHCP Option 82
Enable Option82
Setting
Description
Factory Default
Enable or Disable Enable or disable DHCP Option 82 function.
Disable
Type
Setting
Description
Factory Default
IP
Use switch IP address as the remote ID sub-option.
IP
MAC
Use switch MAC address as the remote ID sub-option.
IP
Client-ID
Use the combination of switch MAC address and IP
address as the remote ID sub-option.
IP
Other
Use the user-defined value as the remote ID sub-option. IP
Value
Setting
Description
Factory Default
Displays the value which you’ve set.
Max. 12 characters If you set the type as Other, you will have to fill it.
switch IP address
Display
Setting
Description
Factory Default
The actual hexdecimal value set at the DHCP server for
the Remote-ID. This value is automatically generated
according to the Value field. Users can not modify it.
COA87FFD
DHCP Function Table
Enable
Setting
Description
Factory Default
Enable or Disable Enable or disable DHCP Option 82 function for this port. Disable
Using Diagnosis
The IE-SW-VL08M provides two important tools for administrators to diagnose network systems.
Mirror Port
The
Mirror port
function can be used to monitor data being transmitted through a specific port.
This is done by setting up another port (the
mirror port
) to receive the same data being transmitted