IE-SW-VL08M Series User’s Manual
Featured Functions
3-5
Name
Setting
Description
Factory Default
Max. 63
Characters
Specify an alias for each port, and assist the
administrator in remembering important
information about the port.
E.g., PLC 1
None
Port Transmission Speed
Setting
Description
Factory Default
Auto
Allows the port to use the IEEE 802.3u protocol
to negotiate with connected devices. The port
and connected devices will determine the best
speed for that connection.
100M-Full
100M-Half
10M-Full
10M-Half
Choose one of these fixed speed options if the
Ethernet device at the other end has trouble
auto-negotiating for line speed.
Auto
FDX Flow Control
This setting enables or disables the flow control capability of this port when the
port transmission
speed
setting is on
auto
mode. The final result will be determined by the
auto
process between the
IE-SW-VL08M and the connected device.
Setting
Description
Factory Default
Enable
Enables the flow control capability of this port
when in auto-nego mode.
Disable
Disables the flow control capability of this port
when in auto-nego mode.
Disable
Port Type
Setting
Description
Factory Default
Auto
Allows the port to auto detect the port type of
the Ethernet device at the other end and change
the port type accordingly.
MDI
MDIX
Choose the MDI or MDIX option if the
Ethernet device at the other end has trouble
auto-negotiating for port type.
Auto
Network
The
Network
configuration allows users to configure both IPv4 and IPv6 parameters for
management access over the network. The IE-SW-VLxxM series supports both IPv4 and IPv6, and
can be managed through either of these address types.