67
6
DETAILED PARAMETER DESCRIPTION
This parameter sets the AC line voltage, that is converted
directly into DC voltage and applied on the motor
terminals during the braking time.
6.3.16 - P35 - DC-Brak-
ing voltage level
(%U
N
)
Factory
Standard
min.
Range
max.
P35 -
DC braking voltage level (% )
shortest step
30%
1%
50%
30
This protection acts limiting the time interval between
starts to avoid excessive starting and stopping conform
time adjusted in parameter P36.
Factory
Standard
min.
Range
max.
P36 -
Time interval between starts
Shortest step
OFF, 1s
1s
999s
2s
6.3.17 -P36 - Time
interval
between starts
Operation by HMI (I/O)
Operation by three wire digital input
(DI1 and DI2)
Attention:
The SSW controller will not accept a new Start command during the time, adjusted in P36, elapses
after Stop. Identically to serial interface communication.