Monitoring
SRW 01 | 6-1
6
6 MONITORING
6.1 MONITORING PARAMETERS
The SRW 01 performs the monitoring of the following variables:
Parameter
(address)
Description
Range
P002
Current % IN
0 to 999 %
P003
True RMS Current
0.0 to 6553.5 A
P004
Average Voltage True RMS
0 to 1000 V
P005
Line Frequency
0.0 to 99.9 Hz
P006
Relay Status (binary)
bit0 = Error
bit1 = Trip
bit2 = Alarm/Fault
bit3 = Motor On
bit4 = Remote Mode
P007
Relay Status 2 (binary)
bit0 = HMI 0 Key
bit1 = HMI I Key
bit2 = Speed Direction/Speed
bit3 = Motor Transition
bit4 = Cooling Time
P008
Power Factor
0.00 to 1.00
P009
Motor Reactive Power
0.0 to 6553.5 kVAr
P010
Motor Active Power
0.0 to 6553.5 kW
P011
Motor Apparent Power
0.0 to 6553.5 kVA
P012
Digital Inputs I11 to I16 Status (decimal)
0 to 63
P013
Digital Outputs O1 to O4 Status (binary)
bit0 = O1
bit1 = O2
bit2 = O3
bit3 = O4
P014
Last Error
0 to 200
P015
Second Error
0 to 200
P016
Current Error
0 to 200
P020
PTC Value (Ohms)
0 to 10000 Ω
P023
Firmware Version (UC)
0.00 to 655.35
P024
Type of Protection (UC)
0 = PTC
1 = ELS
2 = PTC/ELS
P026
Firmware Version (UMC/UMCT)
0.00 to 655.35
P027
Firmware Version (EDU)
0.00 to 655.35
P029
Value of Addressing Switches
0000h to 00FFh
P030
L1 Phase True RMS Current
0.0 to 6553.5 A
P031
L2 Phase True RMS Current
0.0 to 6553.5 A
P032
L3 Phase True RMS Current
0.0 to 6553.5 A
P033
Line Voltage L1-L2
0 to 1000 V
P034
Line Voltage L2-L3
0 to 1000 V
P035
Line Voltage L3-L1
0 to 1000 V
P036
Earth Leakage Percentage Current
0 to 3334 %
P037
Earth Leakage True RMS Current
0.000 to 10.000 A
P042
Powered Relay Time
0 to 65530 h
P043
Motor Running Time
0 to 65530 h
P044
Meter kWh
0.0 to 999.9 kWh
P045
Meter MWh
0 to 65535 MWh
P046
Meter kVArh
0.0 to 999.9 kVArh
P047
Meter MVArh
0 to 65535 MVArh
P050
Motor Thermal Protection
0 to 100 %
P051
Current Imbalance Level
0 to 100 %
P052
Earth Fault Level
0 to 200 %
P053
Voltage Unbalance Level
0 to 100 %
Summary of Contents for SRW 01