41
95-03009
MAINTENANCE
HOUSING DISASSEMBLY
RETAINING
RING
HOUSING
Figure 4
IMPELLER ASSEMBLY
HOUSING
CASING
RETAINER BOLT
O-RING
Figure 7
DISASSEMBLY
Refer to pages 19-23 for Type 1, 1C and Type 4
pump seal procedures.
1. Release clamp and remove casing. Remove
impeller retainer bolt and O-ring. Pull impeller/
backplate assembly off bearing housing shaft.
(Figure 4)
2. Remove the coupling covers (cap screws).
Loosen the set screws on the pump coupling.
(Figure 5)
3.
Style B
; Remove bolts from adapter and
stand. Remove housing and stand as a unit.
Style C
; Remove stand/housing assembly, than
remove end cap. (See Figure 10 for end cap).
3. Push the shaft and bearing assembly out of
the housing from the impeller end. (Figure 7)
4. Remove the retaining ring and press the
bearings off the shaft. (Figure 7)
WARNING
TO AVOID SERIOUS INJURY, DO NOT
INSTALL OR SERVICE PUMP UNLESS
ALL POWER IS OFF AND LOCKED OUT.
Figure 5
COVERS
SETSCREWS
MOTOR
CAP SCREWS
Summary of Contents for 200 series
Page 2: ...95 03009 THIS PAGE IS INTENTIONALLY LEFT BLANK 7 12 96 ...
Page 25: ...24 95 03009 MAINTENANCE SEE PAGE 34 MOTOR MOUNTS ELECTRIC MOTORS ...
Page 26: ...25 95 03009 MAINTENANCE SEE PAGE 34 MOTOR MOUNTS ELECTRIC MOTORS ...
Page 30: ...29 95 03009 AVAILABLE SEALS FOR 200 SERIES PARTS LISTS Figure 38 ...
Page 40: ...39 95 03009 THIS PAGE IS INTENTIONALLY LEFT BLANK INSTALLATION DIMENSIONS Style A 7 12 96 ...