Version 1.0
PN: 2042-8198
Page 21 of 75
DN: 10-32813
Figure 17 - Dashboard: Settings for Ethernet
10.
Close Dashboard and remove the USB cable from the RMA PLUS.
11.
Reset the RMA PLUS.
12.
Connect an Ethernet cable from your PC to either port of the RMA PLUS. NOTE: The
PC’s network
interface configuration is outside the scope of this document. It should be configured for a static IP
address on the same subnet taking care to avoid addresses 192.168.0.xxx (where xxx != 1, 100 or
255 for the last octet in this example). NetBIOS is also recommended.
13.
Launch Dashboard.
14.
The RMA PLUS and any devices connected to the high-speed Watbus network are now discovered
under the “Ethernet Devices” tree node.
Expand the RMA PLUS to see device information including
the Ethernet address.