MODEL/PART DESIGNATIONS
BRAND NAME
DESCRIPTION
MODEL -
PART NUMBER
ECOSTREAM
Counter Top
ECOSTREAM Counter Top
–
Cold, Hot
WL2100IT-M-CTN
F-2100-M-HC-UT-GY-CTN
Serial Number Prefix: I
A2H221GR
ECOSTREAM
Tower
ECOSTREAM Tower
–
Cold, Hot
WL2100IT-FS-CTN
F-2100-FS-HC-UT-GY-CTN
Serial Number Prefix: I
A1H221GR
SPECIFICATIONS
ITEM
ECOSTREAM Counter Top
ECOSTREAM Tower
Water Connection
¼” Quick Connect
Cold Water Temperature
Cold Water Temperature – Factory Set Point 5°C (41°F)
Adjustable - 1.1° - 12.2°C (34°
-
54°
F.)
Cold Tank Size
Tower: 4 Liters (1.1 Gallons)
Counter Top: 2 Liters (.53 Gallons)
Hot Water Temperature
85°C (185°F) Factory Set Point
Hot Water Manual Reset
Overload
105°C (221°F)
Hot Tank Size
1.6 Liters (.42 Gallons)
Recommended Service
Pressure
40-60 psi (275-414 kPa) – Use Pressure Regulator
Maximum Service Pressure 100 psi (689 kPa) – Use Pressure Regulator
Rated Service Flow
1.89 Liters per Minute (0.5 gallons per minute)
Environmental Temperature 2° - 37°C (35° - 100°F)
UV Lamp
4 Watts
8 Watts
Heater
500 W
Refrigerant Gas
R134a, 38g, 1.34 ounces
R134a, 38g, 1.34 ounces
R134a Pressures
High (230 psi), Low (90 psi)