ECOSTREAM COUNTER TOP DRAINING INSTRUCTIONS
Draining Notes
Drain the
ECOSTREAM
Water Treatment System
for transportation.
WARNING!
STORE UNIT EMPTY. ALWAYS SANITIZE BEFORE REUSE.
The unit must be completely drained and sealed before storing to avoid stagnation and
reduce microbial growth).
Prior to draining the hot tank, turn off the Red Heater and Compressor Power
Switch (
O=OFF)
, and dispense 2 liters of hot water from the machine. As hot water
is dispensed from the faucet of the
ECOSTREAM Water Treatment System
, colder
water will be introduced into the hot tank. Since the Red Heater and Compressor
Power Switch is turned off, the heater will not energize and heat the incoming tap
water. Following this precaution prevents exposing personnel and equipment
(drains, catch basin, etc.) to scalding hot water.
Disable Cold and Hot Tanks
1.
Turn off the Red Heater and Compressor Power Switch (
O-OFF
) to disable the
heater and compressor.
2.
Dispense 2 liters (1/2 Gallon) of water through the hot tank to cool the water
temperature in the hot tank and avoid burns.
WARNING!
HOT WATER.
The
ECOSTREAM
Water Treatment System
produces Hot
Water up to 87
°
C (188
°
F).
Water above 52
°
C (125
°
F) can cause severe burns or scalding.
Hot water should be dispensed carefully into insulated container to avoid injury.
Turn off Water Supply and Bleed Water Pressure
3.
Isolate the
ECOSTREAM
Water Treatment System
from
feed water by turning off the supply.
4.
Dispense cold still water to relieve any pressure built up in
the system.
5.
Remove the water supply line from the inlet line bulkhead
fitting at back of the
ECOSTREAM
Water Treatment
System.
6.
Depress Cold Water Dispense Button until all Cold Water has drained from the
ECOSTREAM
Water Treatment System.
7.
Depress Hot Water Dispense Button until all Hot Water has drained from the
ECOSTREAM
Water Treatment Machine
.
Water Supply Line