COLD WATER TROUBLESHOOTING INDEX
1.
Cold Water is not Cold (41° +/- 5° F)
1.
Cold Water is not Cold (41
°
+/- 5
°
F)
Possible Reason
Solution
No power or refrigeration
elements
Check that the Red Heater and Compressor
switch is on.
Turn Red Heater and Compressor Switch on.
I = ON
Tank has run out of cold water.
Cold tank capacity is 4 liters for
Tower and 2 liters for Counter
Top.
Wait for cold tank to chill water to temperature prior to
dispensing more cold water.
A greater capacity of
Waterlogic
Water Systems is available.
Cold Water Thermostat
Check continuity of thermostat with multimeter. Replace
thermostat as required.
Refrigerant has run out
Run compressor for at least ten minutes. If condenser is not
warm, then refill the refrigerant.
Compressor problem
If Compressor is not running, repair or replacement is
needed.