8.
Inspect and clean Quartz Sleeve and O-ring.
9.
Reinstall the Quartz Sleeve and Quartz Sleeve Retaining Nut. Tighten firmly to ensure
proper seal. Over-tightening can cause damage.
CAUTION!
DO NOT INSTALL THE UV LAMP AT THIS TIME
The UV will interact with the sanitizer and could potentially cause taste.
10.
Connect 40-60 psi regulated, potable water supply to the water inlet bulkhead fitting
located on the back of the
ECOSTREAM
Water Treatment System.
Turn on water supply
and check for leaks.
DANGER!
ELECTRICAL SHOCK HAZARD.
Do not plug in unit unless qualified. Only qualified personnel who have read and
understand this entire manual should attempt to install or service this unit.
11.
Connect
ECOSTREAM Water Treatment System
to power.
CAUTION!
NEVER TURN ON HEATER BEFORE FILLING HOT TANK.
Red Heater and Compressor Power
Switch must be in the O=OFF
position while the hot tank is empty. Damage could occur within one
minute and the overload (high limit) will require manual reset if heater
is turned on with an empty hot tank.
Fill the Cold Circuit with Sanitizer
12.
Depress the main dispensing button on the front control panel until cold water/sanitizing
solution comes out the faucet.
NOTE:
Container and drain basin will be required to catch
the water from the faucet.
WARNING!
Use Personal Protective Equipment. Gloves and Eye Protection Required.
The first 2 or 3 gallons of water will contain concentrated sanitizer. Use extreme care!
Flushing the Sanitizer from the Machine
13.
Place a pitcher, catch basin, or other container under the faucet of the
ECOSTREAM Water
Treatment System.
14.
Flush the Cold Tank. Run several gallons of water through the faucet by dispensing cold
water to dilute and remove the sanitizer from the cold circuit. You can use chlorine test
strips to evaluate the water.
15.
Once the sanitizer odor/taste has been flushed out of the cold side of the machine the
sanitization process for the Cold Circuit is complete.