Fill the Hot Tank
16.
Press the Hot Water Select Button, followed by the main dispensing button to fill the hot
tank. Water will dispense from the faucet once the hot tank is full. Flush until water is
clear.
WARNING!
HOT CIRCUIT IS NOT SANITIZED.
Water in the hot circuit is not sanitary until the temperature exceeds 77
o
C (171
o
F) for at
least 5 minutes.
UV System Functional Test
WARNING!
ULTRAVIOLET RADIATION.
Protect your skin and eyes against ultraviolet
rays. Never look directly at an operating UV light. Disconnect wiring before removing.
17.
Reinstall the UV Lamp and connect the wiring.
18.
Dim or shield the overhead lights and peer into the machine, on top of the Cold Tank, at the
UV connector and retaining cap. The blue glow indicates that the lamp is lit.
Compressor Test
19.
Switch Red Compressor / Heater to
I=ON position
. Always ensure tanks are
full of water before turning on the heater or the overload (high limit) will
open and require manual reset. If the wire condenser at back of the
ECOSTREAM
Water Treatment System
is warm, the refrigeration system is
working.
20.
Once the machine reaches its target temperature, the compressor will shut off. Draw a
glass of cold water and verify it is has been chilled to proper temperature.
Heater Test
21.
Always ensure tanks are full of water before turning on the heater or the overload (high
limit) will open and require manual reset. It will take the heater approximately 10 minutes
to heat the water from ambient 24°C (75°F) to the factory set point of 85°C (185°F).
Dispense a cup of hot water to ensure the temperature/odor/taste is acceptable.
WARNING!
HOT WATER. Unit produces Hot Water up to 87
°
C (188
°
F).
Water above
52
°
C (125
°
F) can cause severe burns or scalding. Hot water should be dispensed
carefully into insulated container to avoid injury.