Ecostream
Manual
Page 40 - Revision: 11-13-2020
frequently than a location with little to no sediment. Be sure to replace your filters whenever
you notice a decline in the performance, whether it is a drop in flow rate and/or pressure or
an unusual taste in the water.
2.
Flush thoroughly per filter manufacturers’ recommendation with fresh water to drain.
3.
Once flushed, install the filters. Following the flow direction on the filter.
NOTE:
Filters should not be flushed prior to 24 hours before installation to limit Microbial
Growth.
Sanitizing
Sanitize using a Household Bleach (5.25% Sodium Hypochlorite solution) or other approved
cleaner throughout the cold and sparkling water circuits. Follow all instructions on the
sanitizer and flush with fresh water through the faucet until odor and taste is acceptable.
WARNING!
USE PROPER PERSONAL PROTECTIVE EQUIPMENT
Always ensure proper ventilation and use proper personal protective equipment such as
gloves and eye protection when using chemicals. Refer to Material Safety Data Sheet for
specific requirements of each chemical product. Take all necessary precautions to
prevent sanitizer from contacting eyes, clothing, and any other surfaces in could damage
(carpets).
4.
Disconnect the UV Lamp wiring harness and carefully remove the UV Lamp from the quartz
sleeve.
CAUTION!
UV SYSTEM IS FRAGILE.
Never handle the UV System with bare hands. UV
Lamp and Quartz Sleeve must be free of oils and contaminants to ensure proper
operation.
5.
Unscrew Cold Tank/Quartz Sleeve retaining cap
and remove the Quartz Sleeve. This will require
Top Cover to be removed to access properly and
facilitate removal.
6.
Mix ½ gallon of sanitizer per directions or use Bleach Solution (1 teaspoon = 1/6 oz. = 5 ml =
½ cap full) of household bleach (Sodium Hypochlorite 5 - 10% Concentration) with 1/2
gallon of water. Always ensure sanitizer is compatible with stainless steel and acetyl plastic.
7.
Pour sanitizer solution through UV Port into Cold Tank with a funnel or spout. You may add
concentrated sanitizer (½ cap bleach) directly into empty cold tank instead of premixing.
UV Port
Retaining Cap