background image

Backwashable Filter System Setup - Econo 

 

Installers Displays & Settings (1-99 Days Between Regeneration option) 

 
 

 

 

STEP 11D 

– From normal mode, press SET HOUR + UP buttons simultaneously for 3  

 

 

 

 

seconds and release. 

 
 

STEP 21D 

– Regeneration Time:

 

Set the clock to the hour the regeneration should occur by using the 

UP or DOWN buttons. An arrow points to PM after 12. Press SET HOUR to go to STEP 31D. 

 
 
 
 

STEP 31D 

– Days to Regen: Set the number of days between regenerations. The allowable range is 1 

to 99. Press SET HOUR to exit Installer Displays & Settings. 

 

 

 

Installer Displays & Settings (7 day option) 

 

STEP 117

 – From normal mode, press SET HOUR + UP buttons simultaneously for 3  

 

 

 

seconds and release. 

 
 
 
 

STEP 217

 – Regeneration Time: Set the clock to the hour the regeneration should occur by using the 

UP or Down buttons. An arrow points to PM after 12. Press SET HOUR to go to STEP 317. 

 

 

 

 

 

 

STEP 317 

– Current Day of the week: Set the current day of the week by using  

 

 

 

the UP or DOWN buttons (see chart at right for date codes). Press SET HOUR  

 

 

 

to go to STEP 417 

 
 
 
 
 

 

 

STEP 417 

– Sunday Regeneration: To regenerate on Sunday use the UP or DOWN 

 

 

 

Button until the arrow points to Regen. If the arrow does not point to Regen a 

 

 

 

Regeneration will not occur on Sunday. Press SET HOUR to go to STEP 517. 

 
 
 
 

 

 

STEP 517 

– Monday Regeneration: To regenerate on Monday use the UP or DOWN 

 

 

 

button until the arrow points to Regen. If the arrow does not point to Regen a regeneration 

 

 

 

will not occur on Monday. Press SET HOUR to go to STEP 617. 

 

 

 

 

 

 
 

 

 

 

 

 
 

 

 

 

 

 

 

 

STEP 617 

– Tuesday Regeneration: To regenerate on Tuesday use the UP or DOWN 

 

 

 

button until the arrow points to Regen. If the arrow does not point to Regen a  

 

 

 

 

 

regeneration will not occur on Tuesday. Press SET HOUR to go to STEP 717. 

 
 
 
 
 

 

 

STEP 717

 – Wednesday Regeneration: To regenerate on Wednesday use the UP or  

 

 

 

 

DOWN button until the arrow points to Regen. If the arrow does not point to Regen a 

 

 

 

Regeneration will not occur on Wednesday. Press SET HOUR to go to STEP 817. 

 
 

 

 

STEP 817

 – Thursday Regeneration: To regenerate on Thursday use the UP or DOWN 

 

 

 

 

 

 

 

 

 

 

 

 

 

13 

Summary of Contents for ECONO Series

Page 1: ...TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN ANNUAL PREVENTA...

Page 2: ...ration 5 Consumer Valve Programming Set up 7 Backwashable Filter System Setup 8 Backwashable Filter Setting Options 10 Econo Control Valve Function and Cycles of Operation 12 Backwashable Filter Syste...

Page 3: ...T SERIES 1500 CONTRO VALVE AND MEDIA SPECIFICATIONS BTC1 BTC2 BTMC1 MINERAL TANK SIZE 10 x 44 12 x 52 10 x 44 MEDIA CU FT 1 0 cu ft 2 0 cu ft 1 0 cu ft OPERATING PRESSURE 40 100 PSI 40 100 PSI 40 100...

Page 4: ...onics and establishes the service piston position The display should flash all wording then flash the software version e g 154 and then reset the valve to the service position All plumbing should be d...

Page 5: ...E NUT If the fitting is leaking tightening the nut will not stop the leak Remove the nut remove the fitting and check for damage or misalignment of the o ring Do not use pipe dope or other sealant on...

Page 6: ...6...

Page 7: ...the steps as shown to the UP or DOWN An arrow points to PM the right Access the mode by pressing during p m hours Simultaneously press SET HOUR and UP simultaneously for SET HOUR and DOWN to return t...

Page 8: ...on the valve is activated To unlock press NEXT and CLOCK in sequence then press NEXT and simultaneously for 3 seconds and release Step 2F Choose FILTERING using the or buttons Press NEXT to go to Step...

Page 9: ...after a set period of time The start of regeneration is de ned as the rst backwash cycle Dn brine cycle or UP brine cycle which ever comes rst Set Gal on Relay activates after a set number of gallons...

Page 10: ...displays normally rotate however pressing NEXT will pause on the selected display for 5 minutes Pressing NEXT will alternate between the displays One of the displays is always the current time of day...

Page 11: ...set to on 0 there is no set delayed regeneration time so REGEN TODAY will not activate if REGEN button is pressed To initiate a manual regeneration immediately press and hold the REGEN button for thr...

Page 12: ...d pliers Disassembly for servicing takes much less time than comparable products currently on the market Control valve installation is made easy because the distributor tube can be cut above to below...

Page 13: ...day of the week by using the UP or DOWN buttons see chart at right for date codes Press SET HOUR to go to STEP 417 STEP 417 Sunday Regeneration To regenerate on Sunday use the UP or DOWN Button until...

Page 14: ...es not point to Regen a regeneration will not occur on Friday Press SET HOUR to go to STEP 1017 STEP 1017 Saturday Regeneration To regenerate on Saturday use the UP or DOWN button until the arrow poin...

Page 15: ...e the system sooner than when the system calls for it usually referred to as a manual regeneration There may be a period of heavy water usage because of guests or a heavy laundry day To initiate a man...

Page 16: ...position d Press SET HOUR and DOWN for 3 seconds or unplug power source jack black wire from the circuit board and plug back into reset control valve e Motor not inserted fully to engage pinion motor...

Page 17: ...es when UP and DOWN buttons are depressed 8 Smell and or Iron bleeding thru a Size of equipment correct b Check media a Chlorinate hot tank 9 Smell Hot side only b Optional to remove anode rod c If co...