background image

User Displays - Econo 

 

General Operation 

 
When the system is operating one of two displays will be shown. Pressing UP or DOWN button will alternate between the displays. 
One of the displays is always the current time of day (to the nearest hour). The second display is the days remaining until next 
regeneration. If the days remaining is equal to one, a regeneration will occur at the next preset regeneration time. The user can scroll 
between displays as desired. 
 
If the system has called for a regeneration that will occur at the present time of regeneration, the arrow will point to Regen. 
 
Regeneration Mode 
 
Typically a system is set to regenerate at a time of low water usage. An example of a time with low water usage is when a household 
is asleep. If there is a demand for water when the system is regenerating, untreated water will be used. 
 
When the system begins to regenerate, the display will change to indicate the cycle of the regeneration process (see Table 3) that is 
occurring and an arrow will also point to Regen. The system will run through the steps automatically and will reset itself provide 
treated water when the regeneration is completed. 
 

 

Manual Regeneration 

 
Sometimes there is need to regenerate the system, sooner than when the system calls for it,  
usually referred to  as a manual regeneration. There may be a period of heavy water usage  
because of guests or a heavy laundry day. 
 
To initiate a manual regeneration at the preset delayed regeneration time, simultaneously  
press UP-DOWN buttons together and release. The arrow will point to the word Regen if  
a regeneration is expected "tonight". To cancel the regeneration simultaneously 
 press UP + DOWN buttons and release. 
 
To initiate a manual regeneration immediately, simultaneously press UP + DOWN buttons 
 together for three seconds. The system will begin to regenerate immediately. The request 
 cannot be cancelled. Note: For softeners, if brine tank does not contain salt, fill with salt 
 and wait at least two hours before regenerating. 
 

Set Time of Day 

 

STEP 1U

 – Press SET HOUR 

 
 

STEP 2U 

– Current: Set the clock to the closest hour by using the UP and DOWN button. An arrow points to PM after 12.  After a 

power outage, the time of day will need to be reset. Press SET HOUR to exit. 
 
 

Power Loss 

 
If the power goes out current timer of day will need to be reset. If the power goes out while the system is regenerating, the cycle 
picks up where it was interrupted when the power returns. Note: The display will flash if a power outage has occurred. 
 
 

Error Message 

 
If "E1," "E2" or "E3" appears on the display contact the help. 
This indicates that the valve did not function properly. 
 

 

 

 

 
 
 

 

 

15 

Summary of Contents for ECONO Series

Page 1: ...TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN ANNUAL PREVENTA...

Page 2: ...ration 5 Consumer Valve Programming Set up 7 Backwashable Filter System Setup 8 Backwashable Filter Setting Options 10 Econo Control Valve Function and Cycles of Operation 12 Backwashable Filter Syste...

Page 3: ...T SERIES 1500 CONTRO VALVE AND MEDIA SPECIFICATIONS BTC1 BTC2 BTMC1 MINERAL TANK SIZE 10 x 44 12 x 52 10 x 44 MEDIA CU FT 1 0 cu ft 2 0 cu ft 1 0 cu ft OPERATING PRESSURE 40 100 PSI 40 100 PSI 40 100...

Page 4: ...onics and establishes the service piston position The display should flash all wording then flash the software version e g 154 and then reset the valve to the service position All plumbing should be d...

Page 5: ...E NUT If the fitting is leaking tightening the nut will not stop the leak Remove the nut remove the fitting and check for damage or misalignment of the o ring Do not use pipe dope or other sealant on...

Page 6: ...6...

Page 7: ...the steps as shown to the UP or DOWN An arrow points to PM the right Access the mode by pressing during p m hours Simultaneously press SET HOUR and UP simultaneously for SET HOUR and DOWN to return t...

Page 8: ...on the valve is activated To unlock press NEXT and CLOCK in sequence then press NEXT and simultaneously for 3 seconds and release Step 2F Choose FILTERING using the or buttons Press NEXT to go to Step...

Page 9: ...after a set period of time The start of regeneration is de ned as the rst backwash cycle Dn brine cycle or UP brine cycle which ever comes rst Set Gal on Relay activates after a set number of gallons...

Page 10: ...displays normally rotate however pressing NEXT will pause on the selected display for 5 minutes Pressing NEXT will alternate between the displays One of the displays is always the current time of day...

Page 11: ...set to on 0 there is no set delayed regeneration time so REGEN TODAY will not activate if REGEN button is pressed To initiate a manual regeneration immediately press and hold the REGEN button for thr...

Page 12: ...d pliers Disassembly for servicing takes much less time than comparable products currently on the market Control valve installation is made easy because the distributor tube can be cut above to below...

Page 13: ...day of the week by using the UP or DOWN buttons see chart at right for date codes Press SET HOUR to go to STEP 417 STEP 417 Sunday Regeneration To regenerate on Sunday use the UP or DOWN Button until...

Page 14: ...es not point to Regen a regeneration will not occur on Friday Press SET HOUR to go to STEP 1017 STEP 1017 Saturday Regeneration To regenerate on Saturday use the UP or DOWN button until the arrow poin...

Page 15: ...e the system sooner than when the system calls for it usually referred to as a manual regeneration There may be a period of heavy water usage because of guests or a heavy laundry day To initiate a man...

Page 16: ...position d Press SET HOUR and DOWN for 3 seconds or unplug power source jack black wire from the circuit board and plug back into reset control valve e Motor not inserted fully to engage pinion motor...

Page 17: ...es when UP and DOWN buttons are depressed 8 Smell and or Iron bleeding thru a Size of equipment correct b Check media a Chlorinate hot tank 9 Smell Hot side only b Optional to remove anode rod c If co...

Reviews: