Water Depot ECONO Series Owner'S Manual Download Page 9

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Step 7F 

– Set Volume Capacity using the 

 

or 

 

button. If value is set to: 

• “oFF” regeneration will be based solely on the day override set (see Installer Display/Settings 
Step 3I); or 
• as a number (allowable range 20 to 250,000) regeneration initiation will be based off the 
value specified. Increment increase is 20 for the range 20 to 2,000, 100 for the range of 2,000 
to 10,000, 500 for the range 10,000 to 50,000 and 2,000 for the range of 50,000 to 250,000. 
See Table 9 for more detail. Press NEXT to go to Step 8F. Press REGEN to return to previous 
step.

 

 
 
Step 8F 

– Set Regeneration Time Options using the 

 

or 

 

button. If value is set to: 

• “NORMAL” means regeneration will occur at the preset time; 
• “on 0” means regeneration will occur immediately when the gallons capacity reaches 0 
(zero); or 
• “ on 0” means regeneration will occur at one of the following: 
— the preset time when the gallons capacity falls below the reserve or the specified number of 
days between regenerations is reached whichever comes first; or 
— after 10 minutes of no water usage when the gallon capacity reaches 0 (zero). 
See Table 9 for more detail. Press NEXT to go to Step 9F. Press REGEN to return to previous 
step. 

STEP 8F 

 

 

 

 

Displays 9F, 10F and 11F are unique to the V3353HR WS1HR PC Board w/Relay. See 
WS1HR&HS  & WS1.25HR&HS Front Cover and Drive Assembly diagram. If using  a  CLK 
V3353HS WS1HS PC Board proceed to Step 12F. 
 

Step 9F: 

Set Relay operation using the 

 

or 

 

button. The choices are: 

• Set Time on: Relay activates after a set time at the beginning of a regeneration and then 
deactivates after a set period of time. The start of regeneration is de. ned as the . rst backwash 
cycle, Dn brine cycle or UP brine cycle which ever comes . rst. 
• Set Gal on: Relay activates after a set number of gallons has been treated and then 
deactivates after a set period of time or after the meter stops registering . ow, whichever comes 
. rst. 
• Off: If set to Off, Steps 10F and 11F will not be shown. 
Press NEXT to go to Step 10F. Press REGEN to return to previous step. 

 
Step 10F: 

Set Relay Actuation Time or Gallons using the 

 

or 

 

buttons. The choices are: 

• Relay Actuation Time: After the start of a regeneration the amount of time that should pass 
prior to activating the relay. The start of regeneration is de. ned as the . rst backwash cycle, Dn 
brine cycle or UP brine cycle which ever comes . rst. Ranges from 1 second to 200 minutes. 
•Relay Actuation Gallons: Relay activates after a set number of gallons has passed through the 
meter when the valve is in the Service mode. Ranges from 1 to 50 gallons. 
Press NEXT to go to Step 11F. Press REGEN to return to previous step. 

 
Step 11F: 

Set Relay Deactivate Time using the 

 

or 

  

buttons. 

• If Set Time on is selected in Step 9F the relay will deactivate after the time set has expired. 
Ranges from 1 second to 200 minutes. 
• If Set Gal on is selected in Step 9F the relay will deactivate after the time set has expired or 
after  the  meter stops registering . ow, whichever comes . rst. Ranges from 1 second to 20 
minutes. 
Press NEXT to go to Step 12F. Press REGEN to return to previous step.

 

 

Step 12F: 

Set the Service Call Indicator by using the 

  

or 

 

buttons. 

Range is in ¼ of a year increments from 0.25 to 9.75 years. Selecting 
OFF will disable this feature. Press NEXT to exit Filter System 
Setup. Press REGEN to return to previous step.

 

 

 

 

Summary of Contents for ECONO Series

Page 1: ...TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN ANNUAL PREVENTA...

Page 2: ...ration 5 Consumer Valve Programming Set up 7 Backwashable Filter System Setup 8 Backwashable Filter Setting Options 10 Econo Control Valve Function and Cycles of Operation 12 Backwashable Filter Syste...

Page 3: ...T SERIES 1500 CONTRO VALVE AND MEDIA SPECIFICATIONS BTC1 BTC2 BTMC1 MINERAL TANK SIZE 10 x 44 12 x 52 10 x 44 MEDIA CU FT 1 0 cu ft 2 0 cu ft 1 0 cu ft OPERATING PRESSURE 40 100 PSI 40 100 PSI 40 100...

Page 4: ...onics and establishes the service piston position The display should flash all wording then flash the software version e g 154 and then reset the valve to the service position All plumbing should be d...

Page 5: ...E NUT If the fitting is leaking tightening the nut will not stop the leak Remove the nut remove the fitting and check for damage or misalignment of the o ring Do not use pipe dope or other sealant on...

Page 6: ...6...

Page 7: ...the steps as shown to the UP or DOWN An arrow points to PM the right Access the mode by pressing during p m hours Simultaneously press SET HOUR and UP simultaneously for SET HOUR and DOWN to return t...

Page 8: ...on the valve is activated To unlock press NEXT and CLOCK in sequence then press NEXT and simultaneously for 3 seconds and release Step 2F Choose FILTERING using the or buttons Press NEXT to go to Step...

Page 9: ...after a set period of time The start of regeneration is de ned as the rst backwash cycle Dn brine cycle or UP brine cycle which ever comes rst Set Gal on Relay activates after a set number of gallons...

Page 10: ...displays normally rotate however pressing NEXT will pause on the selected display for 5 minutes Pressing NEXT will alternate between the displays One of the displays is always the current time of day...

Page 11: ...set to on 0 there is no set delayed regeneration time so REGEN TODAY will not activate if REGEN button is pressed To initiate a manual regeneration immediately press and hold the REGEN button for thr...

Page 12: ...d pliers Disassembly for servicing takes much less time than comparable products currently on the market Control valve installation is made easy because the distributor tube can be cut above to below...

Page 13: ...day of the week by using the UP or DOWN buttons see chart at right for date codes Press SET HOUR to go to STEP 417 STEP 417 Sunday Regeneration To regenerate on Sunday use the UP or DOWN Button until...

Page 14: ...es not point to Regen a regeneration will not occur on Friday Press SET HOUR to go to STEP 1017 STEP 1017 Saturday Regeneration To regenerate on Saturday use the UP or DOWN button until the arrow poin...

Page 15: ...e the system sooner than when the system calls for it usually referred to as a manual regeneration There may be a period of heavy water usage because of guests or a heavy laundry day To initiate a man...

Page 16: ...position d Press SET HOUR and DOWN for 3 seconds or unplug power source jack black wire from the circuit board and plug back into reset control valve e Motor not inserted fully to engage pinion motor...

Page 17: ...es when UP and DOWN buttons are depressed 8 Smell and or Iron bleeding thru a Size of equipment correct b Check media a Chlorinate hot tank 9 Smell Hot side only b Optional to remove anode rod c If co...

Reviews: