Econo Control Valve Function and Cycles of Operation

 

 

This glass filled Noryl fully automatic control valve is designed as the primary control center  to direct and regulate all cycles of a 
water softener or filter. 
 
The time clock control valve can be set to perform downflow regeneration or simply backwash. The time clock control valve has two 
calendar options for regeneration frequency: 
1. an option where the user can choose the number of days (1-99) between each regeneration, and 
2. a seven-day option where the user can choose which day(s) of the week a regeneration should occur. 
 
The control valve is compatible with a variety of regenerants and resin cleaners. The control valve is capable of routing the flow of 
water in the necessary paths to regenerate or backwash water treatment systems. The injector regulates the flow of brine or other 
regenerants. The control valve regulates the flow rates for backwashing, rinsing and the replenishing of treated water into a 
regenerant tank,  when applicable. 
 
The control valve is designed to deliver high service (27gpm @ 15 psig) and backwash (27gpm @25psig) flow rates when the by 
pass has straight fittings. The control valve uses no traditional fasteners (e.g. screws), instead clips, threaded caps and nuts and 
snap type latches are used. Caps and nuts only need to be firmly hand tightened because radial seals are used. Tools required to 
service the valve include one small blade screw driver, one large blade screw driver, pliers and a pair of hands. A plastic wrench is 
available which eliminates the need for screwdrivers and pliers. Disassembly for servicing takes much less time than comparable 
products currently on the market. Control valve installation is made easy because the distributor tube can be cut ½ " above to ½ " 
below the top of tank thread. The distributor tube is held in place by an o-ring seal and the control valve has a bayonet lock feature 
for upper distributor baskets. 
 
The transformer power pack comes with a 15 foot power cord and is designed for use with the control valve. The transformer power 
pack is for dry location use only. If the power goes out, only the time of day needs to reset. All other values are permanently stored in 
the nonvolatile memory. 
 
Table 3 shows the time for the backwash, regenerative, and rinse cycles for the ten available programming options. Six different 
programs are available for a softener, one for a regenerative filter, and three programs for backwash only filters. When the control 
valve is used as a: 
1. softener, one or two backwashes occur and refill always occurs after the rinse cycle (P0 through P5); 
2. regenerative filter, one backwash occurs and refill always occurs after the rinse cycle (P6); and 
3. backwashing filter, one backwash occurs (P7 through P9). 

 

 

Regeneration Cycles and Times for Different Programs 

 

 

 

 

All Times in Minutes 

 

 

Program 

 

C1 

1

st

 Backwash 

C2 

Regenerate 

C3 

2

nd

 Backwash 

C4 

Rinse 

C5 
Fill 

P0 

50 

1-99 

P1 

50 

1-99 

P2 

70 

10 

1-99 

P3 

12 

70 

12 

1-99 

P4 

10 

50 

Skipped 

1-99 

P5 

50 

Skipped 

1-99 

P6 

12 

Skipped

 

12 

1-99 

P7 

Skipped 

Skipped

 

Skipped 

P8 

10 

Skipped 

Skipped

 

Skipped 

P9 

14 

Skipped 

Skipped

 

Skipped 

 

 

 

           Note: During regeneration the display will show C1, C2, etc, etc. If the cycle is skipped, that 

 

           Cycle number will not be displayed. 

 

Please Note: 
8" Should Be use preset P9 and 10" units should use preset P9 
 
 
 
 

 
 
 
 

 

 

12 

Summary of Contents for ECONO Series

Page 1: ...TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN ANNUAL PREVENTA...

Page 2: ...ration 5 Consumer Valve Programming Set up 7 Backwashable Filter System Setup 8 Backwashable Filter Setting Options 10 Econo Control Valve Function and Cycles of Operation 12 Backwashable Filter Syste...

Page 3: ...T SERIES 1500 CONTRO VALVE AND MEDIA SPECIFICATIONS BTC1 BTC2 BTMC1 MINERAL TANK SIZE 10 x 44 12 x 52 10 x 44 MEDIA CU FT 1 0 cu ft 2 0 cu ft 1 0 cu ft OPERATING PRESSURE 40 100 PSI 40 100 PSI 40 100...

Page 4: ...onics and establishes the service piston position The display should flash all wording then flash the software version e g 154 and then reset the valve to the service position All plumbing should be d...

Page 5: ...E NUT If the fitting is leaking tightening the nut will not stop the leak Remove the nut remove the fitting and check for damage or misalignment of the o ring Do not use pipe dope or other sealant on...

Page 6: ...6...

Page 7: ...the steps as shown to the UP or DOWN An arrow points to PM the right Access the mode by pressing during p m hours Simultaneously press SET HOUR and UP simultaneously for SET HOUR and DOWN to return t...

Page 8: ...on the valve is activated To unlock press NEXT and CLOCK in sequence then press NEXT and simultaneously for 3 seconds and release Step 2F Choose FILTERING using the or buttons Press NEXT to go to Step...

Page 9: ...after a set period of time The start of regeneration is de ned as the rst backwash cycle Dn brine cycle or UP brine cycle which ever comes rst Set Gal on Relay activates after a set number of gallons...

Page 10: ...displays normally rotate however pressing NEXT will pause on the selected display for 5 minutes Pressing NEXT will alternate between the displays One of the displays is always the current time of day...

Page 11: ...set to on 0 there is no set delayed regeneration time so REGEN TODAY will not activate if REGEN button is pressed To initiate a manual regeneration immediately press and hold the REGEN button for thr...

Page 12: ...d pliers Disassembly for servicing takes much less time than comparable products currently on the market Control valve installation is made easy because the distributor tube can be cut above to below...

Page 13: ...day of the week by using the UP or DOWN buttons see chart at right for date codes Press SET HOUR to go to STEP 417 STEP 417 Sunday Regeneration To regenerate on Sunday use the UP or DOWN Button until...

Page 14: ...es not point to Regen a regeneration will not occur on Friday Press SET HOUR to go to STEP 1017 STEP 1017 Saturday Regeneration To regenerate on Saturday use the UP or DOWN button until the arrow poin...

Page 15: ...e the system sooner than when the system calls for it usually referred to as a manual regeneration There may be a period of heavy water usage because of guests or a heavy laundry day To initiate a man...

Page 16: ...position d Press SET HOUR and DOWN for 3 seconds or unplug power source jack black wire from the circuit board and plug back into reset control valve e Motor not inserted fully to engage pinion motor...

Page 17: ...es when UP and DOWN buttons are depressed 8 Smell and or Iron bleeding thru a Size of equipment correct b Check media a Chlorinate hot tank 9 Smell Hot side only b Optional to remove anode rod c If co...

Reviews: