Econo Control Valve Function and Cycles of Operation
This glass filled Noryl fully automatic control valve is designed as the primary control center to direct and regulate all cycles of a
water softener or filter.
The time clock control valve can be set to perform downflow regeneration or simply backwash. The time clock control valve has two
calendar options for regeneration frequency:
1. an option where the user can choose the number of days (1-99) between each regeneration, and
2. a seven-day option where the user can choose which day(s) of the week a regeneration should occur.
The control valve is compatible with a variety of regenerants and resin cleaners. The control valve is capable of routing the flow of
water in the necessary paths to regenerate or backwash water treatment systems. The injector regulates the flow of brine or other
regenerants. The control valve regulates the flow rates for backwashing, rinsing and the replenishing of treated water into a
regenerant tank, when applicable.
The control valve is designed to deliver high service (27gpm @ 15 psig) and backwash (27gpm @25psig) flow rates when the by
pass has straight fittings. The control valve uses no traditional fasteners (e.g. screws), instead clips, threaded caps and nuts and
snap type latches are used. Caps and nuts only need to be firmly hand tightened because radial seals are used. Tools required to
service the valve include one small blade screw driver, one large blade screw driver, pliers and a pair of hands. A plastic wrench is
available which eliminates the need for screwdrivers and pliers. Disassembly for servicing takes much less time than comparable
products currently on the market. Control valve installation is made easy because the distributor tube can be cut ½ " above to ½ "
below the top of tank thread. The distributor tube is held in place by an o-ring seal and the control valve has a bayonet lock feature
for upper distributor baskets.
The transformer power pack comes with a 15 foot power cord and is designed for use with the control valve. The transformer power
pack is for dry location use only. If the power goes out, only the time of day needs to reset. All other values are permanently stored in
the nonvolatile memory.
Table 3 shows the time for the backwash, regenerative, and rinse cycles for the ten available programming options. Six different
programs are available for a softener, one for a regenerative filter, and three programs for backwash only filters. When the control
valve is used as a:
1. softener, one or two backwashes occur and refill always occurs after the rinse cycle (P0 through P5);
2. regenerative filter, one backwash occurs and refill always occurs after the rinse cycle (P6); and
3. backwashing filter, one backwash occurs (P7 through P9).
Regeneration Cycles and Times for Different Programs
All Times in Minutes
Program
C1
1
st
Backwash
C2
Regenerate
C3
2
nd
Backwash
C4
Rinse
C5
Fill
P0
3
50
3
3
1-99
P1
8
50
8
4
1-99
P2
8
70
10
6
1-99
P3
12
70
12
8
1-99
P4
10
50
Skipped
8
1-99
P5
4
50
Skipped
4
1-99
P6
12
6
Skipped
12
1-99
P7
6
Skipped
Skipped
4
Skipped
P8
10
Skipped
Skipped
6
Skipped
P9
14
Skipped
Skipped
8
Skipped
Note: During regeneration the display will show C1, C2, etc, etc. If the cycle is skipped, that
Cycle number will not be displayed.