36
NOTE: If you attempt to learn in a device that is already learned in, it will be deleted and added to the new zone
eg: If a WPIR is in zone 3 and you wish to move it to zone 5 relearning in zone 5 will delete it from zone 3 and
add it to zone 5.
5.2 Zone Feature Programming
Zone Feature Programming can be used to set all the different combinations of alarm modes.
Simply put the corresponding zones dipswitch up, and press the tamper to change the features. For every press
of the tamper, the feature will increment to the next, the number of beep(s) from the internal screamer heard
correspond to the feature that you have activated:
5.2.1 Zone feature programming
Set the dipswitch for the zone you wish to program.
Press the tamper until the desired feature is reached. For every press of the tamper,
the feature will increment to the next, the number of beep(s) heard correspond to the
feature that you have activated.
Set all the dipswitches to off.
Operating Mode
1
Zone is always active when system is armed
2
Not used
3
Zone is now active in away mode only, disabled in home mode
4
Zone is always active, when system is both armed and disarmed (24 hour zone)
5
Zone is always active when system is armed with a 30 sec entry delay
6
Not used
7
Zone is now active in away mode only with a 30 sec entry delay, disabled in home
mode
5.1.4 Delete a detector
Set the dipswitch to on for the zone you wish to delete. I.e. if you wish to
delete the sensor currently programmed into Zone 1, set dipswitch 1 to on as
shown.
Press the DELETE button.
The unit will beep once to confirm the zone was deleted.
Set all dipswitches to off.
DELETE
D