10
2.2.3 Wireless PIR Detectors
This section shows you how to install wireless PIR detectors (PIRW3) for your system.
a) Systems with packaged wireless PIR detectors should already be learnt into the
Main Control Unit
. If
your detectors have a sticker with a zone number on the back, then they are already learnt into the
system. Follow the
Set-up a pre-learnt wireless PIR detector
procedure for each of these detectors
that you have.
b) If you have purchased additional detectors, you will need to learn them into the
Main Control Unit
.
Follow the
Set-up and learn-in a wireless PIR detector
procedure for each of these detectors that
you have.
Refer to the
Programming
chapter later further in the manual if you wish to change the
Home
and
Away
settings
for a zone.
a) Set-up a pre-learnt wireless PIR detector
Open the front cover of the detector and remove the plastic insulator from the
battery. Wait 3 minutes for the detector to warm up.
Set dipswitches 1 and 3 on the Main Control Unit to ON.
Open and close the front cover of the detector. The detector will now enter
Walk Test
mode.
Walk test the detector and adjust the facing angle as necessary so that the
red light on the detector turns on whenever you walk past it.
The unit will beep out the zone number of the detector whenever it is
triggered (i.e. zone 1 will beep once).
The unit will not beep out the zone number if the radio signal strength is not
strong enough.
Mount the detector if the walk test was successful.
Press button 2 on the remote to exit Walk Test mode.
Set all the dipswitches to off.